VOLT:EXT:SOUR
Sets the constant voltage control mode. This cannot be set when the output is on.
Command
[SOURce:]VOLTage:EXTernal:SOURce
{NONE|VOLTage|RESistance|IRESistance|FVOLtage}
[SOURce:]VOLTage:EXTernal:SOURce?
Parameter
Value NONE
Panel control (default)
VOLTage
External voltage control
RESistance External resistance control 10 kW -> MAX OUT
IRESistance External resistance control 10 kW -> 0 OUT (FAIL SAFE)
FVOLtage
External voltage control (FAST)
For the setting that is applied when *RST is sent, see
.
Note : FVOL parameter is available for 8 kW type products only.
Response
Returns the constant voltage control mode as character data in response to
VOLT:EXT:SOUR?.