VOLT
Sets the voltage.
Command
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
{<numeric>|MINimum|MAXimum}
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]
Parameter
Value 0 % to 105 % of the rated output voltage(The default value is 0 % of the rated
output voltage.)
An SCPI error (-221, "Settings conflict") occurs if
is not set to
NONE.
Unit
V
For the setting that is applied when *RST is sent, see
.
Response
Returns the voltage setting in the NR3 form in response to VOLT?. If the voltage value is set
using external input, the specified voltage is returned.