CURR:TRIG
Sets the current value that is applied when
/
and a software trigger
are sent.
Command
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]? [{MINimum|MAXimum}]
Parameter
Value 0 % to 105 % of the rated output current
(The default value is 105 % of the rated output current.)
Unit
A
For the setting that is applied when *RST is sent, see
.
Response
Returns the current value that is applied when a trigger is received in the NR3 form in
response to CURR:TRIG?.
Overview
Setup
Overview of Messages
Command
(function search)
Protection and Clear the Alarm
Setting Changes using triggers
Command
(ABC search)
Command
(Sub-system search)
Appendix
Tutorial
PAT-T series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
110/158