PAD-L
Specifications
7-11
Type V
PAD
35-200L
PAD
60-120L
PAD
110-60L
Range of operation temperature and humidity
0 to 40 ℃ / 10 to 90 %RH (no dew condensation allowed)
Range of storage temperature and humidity
-10 to 60℃ / 0 to 70 %RH (no dew condensation allowed)
Cooling system
Forced air cooling with fan
Output polarity
Positive or negative grounding possible
Isolation voltage
Insulation resistance
Across chassis and input terminals
500VDC, 30MΩmin.
Across chassis and output terminals
500VDC, 20MΩmin.
Withstanding voltage
Across input terminals and output terminals
Across input terminals and chassis
Meter display
Voltmeter Full scale, Class 1.5 (JIS)
40 V
66 V
120 V
Ammeter Full scale, Class 1.5 (JIS)
200 A
120 A
60 A
Remote control
Output voltage/control voltage ratio
35 V / approx. 10 V
60 V / approx. 10 V
110 V / approx. 10 V
Output voltage/control resistance ratio
35 V / approx. 10kΩ
60 V / approx. 10kΩ
110 V / approx. 10kΩ
Output current/control voltage ratio
200 A / approx. 0.2 V 120 A / approx. 0.36 V 60 A / approx. 0.45 V
Output current/control resistance ratio
200 A / approx. 550 Ω 120 A / approx. 550 Ω 60 A / approx. 550 Ω
Remote sensing
Possible (compensation one way approx. 1.2 V max.)
Master-slave-control parallel operation
Possible
Master-slave-control series operation
Possible
Protective circuit
Operation
POWER switch is turned off.
Trip temperature of thermal protector
Voltage setting range
(standard value)
3 to 38 V
4 to 66 V
5 to 129 V
Trigger pulse width
(standard value)
Input fuse rating
Output fuse rating
200 A
120 A
60 A
Weight
Approx. 188 kg
Approx. 175 kg
Approx. 170 kg
Dimensions
See dimensional drawings.
Accessory
Operation manual
1 copy
Power cord
1 piece, 3-core cabtyre cable (14 mm
2
, approx. 4 m)
Voltage check chip
2 pieces
Guard cap (with one hexagon wrench)
Output terminal cover
1 piece (*5)
*4: Mounted on the unit. With four mounting screws
*5: Mounted on the unit. With two mounting screws
Over voltage
protection (OVP)
130 ℃ at main power transformer
100 ℃ at cooling package
±250 V
Should withstand 1500 VAC, 1 min. with no abnormalities
1 piece (*4)
50 ms
100 A
1 piece
Содержание PAD-L III Series
Страница 4: ...II PAD L...
Страница 16: ...P 6 Preface PAD L...
Страница 17: ...1 1 PAD L Setup 1 1 Chapter 1 Setup Describes the necessary procedure from unpacking to preparation before use...
Страница 40: ...2 12 Precautions and Preparations for Use PAD L...
Страница 86: ...4 34 Applied Operation PAD L...
Страница 93: ...PAD L Names and Functions of Controls 5 7 22 25 23 26 24 21 Fig 5 6 PAD L series PAD250 15L rear panel...
Страница 95: ...PAD L Names and Functions of Controls 5 9 22 26 23 25 21 24 28 29 Fig 5 8 PAD L series PAD110 60L rear panel...
Страница 98: ...5 12 Names and Functions of Controls PAD L...
Страница 130: ...7 14 Specifications PAD L...