7.2
TYPE IV models specifications
Unless otherwise specified, the specifications of the unit are based on the following
conditions.
•
The load is a pure resistance.
•
The - (neg.) output terminal is connected to the GND terminal.
•
The unit should be used after 30 minutes warming-up time.
Standard value and theoretical value do not guarantee performance. They should be
referred to as target values only.
Type IV
PAD
35-100L
PAD
60-60L
PAD
110-30L
PAD
250-15L
Input
Input voltage and frequency
200 VAC±10 %, 50/60 Hz, 1 φ
Power consumption, at 200VAC, rated load Approx. 6.8 kVA Approx. 6.8 kVA Approx. 6.0 kVA Approx. 6.0 kVA
Output
Voltage
Rated voltage
35 V
60 V
110 V
250 V
Variable range
0 to 35 V
0 to 60 V
0 to 110 V
0 to 250 V
Resolution (theoretical value) *1
6 mV
11 mV
18 mV
45 mV
Number of turns of panel control
10 turns
Current
Rated current
100 A
60 A
30 A
15 A
Variable range
0 to 100 A
0 to 60 A
0 to 30 A
0 to 15 A
Resolution (theoretical value) *1
47 mA
30 mA
14.1 mA
7.5 mA
Number of turns of panel control
1 turn, both of coarse and fine adjustment
Constant voltage characteristics
Ripple and noise (5Hz to 1MHz) RMS
0.5 mV
0.5 mV
1 mV
5 mV
0.005 %+1 mV
0.005 %+1 mV
0.005 %+1 mV
0.005 %+2 mV
0.005 %+2 mV
0.005 %+2 mV
0.005 %+2 mV
0.005 %+3 mV
Transient response (standard value) *2, *3
Temperature coefficient (standard value)
50 ppm/℃
Constant current characteristics
Ripple and noise (5Hz to 1MHz) RMS
50 mA
20 mA
10 mA
5 mA
Source effect (to±10% of AC input voltage)
3 mA
3 mA
3 mA
1 mA
Load effect (to 0 to 100% of output voltage)
5 mA
5 mA
5 mA
3 mA
Constant voltage operation indication
C.V, green lamp indication
Constant current operation indication
C.C, red lamp indication
*1: The value is calculated from the number of turns of the wire to wound potentiometer. In practice,
use 3 to 5 times each value as a target.
*2: Measured using the remote sensing function.
*3: Time necessary for output voltage to return to ±(0.05%+10mV) max. of rated value at 5 to 100%
changes of output current.
50 μs
Source effect
(to±10% of AC input voltage) *2
Load effect
(to 0 to 100% of output current) *2
Содержание PAD-L III Series
Страница 4: ...II PAD L...
Страница 16: ...P 6 Preface PAD L...
Страница 17: ...1 1 PAD L Setup 1 1 Chapter 1 Setup Describes the necessary procedure from unpacking to preparation before use...
Страница 40: ...2 12 Precautions and Preparations for Use PAD L...
Страница 86: ...4 34 Applied Operation PAD L...
Страница 93: ...PAD L Names and Functions of Controls 5 7 22 25 23 26 24 21 Fig 5 6 PAD L series PAD250 15L rear panel...
Страница 95: ...PAD L Names and Functions of Controls 5 9 22 26 23 25 21 24 28 29 Fig 5 8 PAD L series PAD110 60L rear panel...
Страница 98: ...5 12 Names and Functions of Controls PAD L...
Страница 130: ...7 14 Specifications PAD L...