4-12 RS-232C Control
KJM6710
• Syntax
Query message:
SYMMETRY:SLICE:LEVEL?
SYM:SLIC:LEV?
Response message
Returns the current setting in response to SYM:SLIC:LEV? in
real numbers (–300 to +300).
TIME:CONST (TIM:CON)
Sets the time constant for conversion into rms values. Or, queries
the current setting.
Program message
• Syntax
Command message:TIME:CONST <{0.01|0.1|1}>
TIM:CON <{0.01|0.1|1}>
Query message:
TIME:CONST?
TIM:CON?
• Program data
Data format:
Real number
Values:
0.01, 0.1, or 1
(Example) Set the time constant for conversion into rms values to 0.1
TIM:CON 0.1
Response message
Returns the current setting in response to TIM:CON? in real num-
bers (0.01, 0.1, or 1).
UIS?
Queries whether measurements cannot be made.
Program message
• Syntax
Query message: UIS?
Response message
Returns the current setting in response to UIS? in real numbers (0
(yes) or 1 (no)).