4-6 RS-232C Control
KJM6710
DELAY:MODE (DEL:MOD)
Sets the delay mode. Or, queries the current setting.
Program message
• Syntax
Command message:DELAY:MODE_<{AUTO
|MANUAL}>
DEL:MOD_<{AUT|MAN}>
Query message:
DELAY:MODE?
DEL:MOD?
• Program data
Data format: Characters
Values:
AUT:
AUTO delay
MAN: MANUAL delay
(Example) Set the delay mode to AUTO.
DEL:MOD AUT
Response message
Returns the current setting in response to DEL:MOD? in charac-
ters (AUT or MAN).
EQ
Turns on/off the equalizer circuit. Or, queries the current setting.
Program message
• Syntax
Command message:EQ_<{ON|OFF}>
Query message:
EQ?
• Program data
Data format: Characters
Values:
ON:
Equalizer circuit on
OFF:
Equalizer circuit off
(Example) Turn on the equalizer circuit.
EQ ON
Response message
Returns the current setting in response to EQ? in characters (ON
or OFF).