Command Reference
Power Measurement Subsystem
120
SEM Offset Measurement Bandwidth
[:SENSe]:SEMask:OFFSet:LIST:BAND-
width|BWIDth:MEASure <Integer>, <Integer>,
<Integer>, <Integer>,<Integer>
[:SENSe]:SEMask:OFFSet:LIST:BAND-
width|BWIDth:MEASure?
Use this command to set the measurement bandwidth of
offset channel in SEM measurement.
Example:
:SENSe:SEMask:OFFSet:LIST:BANDwidth:MEASure
1,1,1,1,1
Key access:
Meas > SEM > Offset/Limit > More > More > Meas BW
SEM Offset Start Freq
[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STARt
<freq>,<freq>,<freq>,<freq>,<freq>
[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STARt?
Use this command to specify start frequency of offset
channel in SEM measurement.
Example:
:SENSe:SEMask:OFFSet:LIST:FREQuency:STARt 2E6,
5E6, 10E6, 1E6, 2E6
Key access:
Meas > SEM > Offset/Limit
> Start Freq
SEM Offset Stop Freq
[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STOP
<freq>,<freq>,<freq>,<freq>,<freq>
[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STOP?
Use this command to specify start frequency of offset
channel in SEM measurement.
Example:
:SENSe:SEMask:OFFSet:LIST:FREQuency:STOP 3E6,
5E6, 8E6,15E6, 20E6
Key access:
Meas > SEM > Offset/Limit > Stop Freq