DDR2(+LP) Compliance Testing Methods of Implementation
175
Differential Signal AC Output Parameters Tests
11
Test References
See Table 23 - Differential AC Output Logic Level in the
JEDEC Standard JESD79-2E
and Table 23 -
Differential AC Output Logic Level in the
JESD208
.
PASS Condition
The measured crossing point value for the differential test signals pair should be within the
conformance limits of V
OX(AC)
value.
Measurement Algorithm
1 Obtain sample or acquire data waveforms.
2 Use Subtract FUNC to generate the differential waveform from the two source inputs.
3 Split read and write bursts of the acquired signal.
4 Take the first valid READ burst found.
5 Find all differential DQS crossings that cross 0V.
6 Use V
TIME
to get the actual crossing point voltage value by using the timestamp obtained.
7 Determine the worst result from the set of V
OX(AC)
measured.
Содержание D9020DDRC
Страница 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Страница 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 40: ...1 Installing the DDR2 Compliance Test Application 40 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 134: ...6 Single Ended Signals VIH VIL Data Mask Tests 118 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 158: ...9 Single Ended Signals Overshoot Undershoot Tests 142 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 186: ...10 Differential Signals AC Input Parameters Tests 170 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 342: ...17 Command and Address Timing CAT Tests 326 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 366: ...19 Calibrating the Infiniium Oscilloscope and Probe 350 DDR2 LP Compliance Testing Methods of Implementation ...