B-22
KLP 073008
-221,”Settings conflict”
Execution error bit 4
E.g. , Invalid password from syst:pass:cen command. or Calibra-
tion state not enabled but CALibrate command received.
-222,“Current, Voltage or Data out of
range”
Execution error bit 4
Value (current or voltage) exceeds power supply rating or (data)
exceeds acceptable command parameters.
-223,”Data format error”
Execution error bit 4
Multiple decimals in digit, Multiple E, etc.
-224,“Illegal parameter value”
Execution error bit 4
For example, OUTP 2 instead of OUTP 1.
-226,“Lists not same length”
Execution error bit 4
During a LIST command, number of DWEL list entries was not
equal to 1 and did not match number of LIST:VOLT or LIST:CURR
entries.
-240,“Hardware error”
Execution error bit 4
Power supply did not respond to command.
-241,”Hardware missing”
Execution error bit 4
Requesting device 2 status (INST:NSEL 2).
-280, “Program Error“
Execution error bit 4
LIST execution error, e.g., program already running.
-282,”Illegal program name”
Execution error bit 4
Executing prog:run without LIST:SEQ command.
-301,”Value bigger than limit”
Device Error bit 3
E.g., requesting a voltage or current exceeds the limit.
-310,”System Failure”
Device Error bit 3
Program checksum incorrect.
-311,”Memory Error”
Device Error bit 3
E.g., power-up NV RAM error, or CALibrate:STORe error.
-313,”Calibration Memory Lost”
Device Error bit 3
No valid calibration found.
-314,”Save/recall memory error”
Device Error bit 3
Using cell other than 1 - 41 for SAV and RCL.
-315,”Configuration Memory Error”
Device Error bit 3
Configuration Memory Error.
-330,”Self Test Failed”
Device Error bit 3
Self test failed.
-340,”Calibration Failure”
Device Error bit 3
Unable to perform auto calibration.
-341,”Non Volatile Mem. CRC error”
Device Error bit 3
Power supply constants may be corrupted; recalibration may be
necessary.
-350,”Queue Overflow”
Device Error bit 3
More than 15 errors are in queue. Error queue was full, error
events have been lost.
-400,”QueryError”
Query Error bit 2
Data requested was lost due to 253 character limit or KLP output
buffer.
-410,”Query interrupted
Query Error bit 2
New command sent before data from previous query read. Previ-
ous query data lost.
-420,”Query Unterminated”
Query Error bit 2
Controller sent query but did not accept data from power supply.
See VOLT? (PAR. B.48), CAL:SAVE (PAR. B.4) commands.
-430,Query Deadlocked
Query Error bit 2
Over 255 characters received in single input string.
TABLE B-4. ERROR MESSAGES (CONTINUED)
ERROR MESSAGE
ESR ERROR BIT SET
(SEE PAR. A.5)
EXPLANATION
Содержание KLP SERIES
Страница 2: ......
Страница 6: ......
Страница 14: ...viii KLP073008 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 20: ...1 6 KLP 073008 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 21: ...KLP 073008 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ......
Страница 40: ......
Страница 86: ......