KLP073008
3-9
3.2.10.2 CONFIGURE POWER SUPPLY AS SLAVE
1. Turn power on. If the unit comes up in setpoint mode (see PAR. 3.2.4), tap either the
CUR-
RENT
or
VOLTAGE
control to take the unit out of setpoint mode (status display goes from
SET
to blank).
2. Using a thin tool (e.g., a paper clip), press the
FUNCTION
switch repeatedly until the status
display reads
M/S
.
3. Tap the
DC OUTPUT
switch once.
• The status display reads either
SERI
(series) or
PARA
(parallel).
• The
DC VOLTS
display shows the number assigned to the unit (1 = master, 2 or above
= slave).
• The
DC AMPERES
display shows the maximum number of units in the configuration.
• The factory default is standalone operation (
DC VOLTS
and
DC AMPERES
show
1
).
4. Specify either
SERI
(series configuration for higher voltage) or
PARA
(parallel configuration
for higher current) to be the same as the master by
holding in
either the
VOLTAGE
or
CUR-
RENT
control and rotate the control. Both connected units must be set the same, either
SERI
or
PARA
.
5. Specify the total number of units in the configuration to 2 by rotating the
CURRENT
control.
6. Specify the unit number to be assigned ( 2 = slave) by rotating the
VOLTAGE
control.
7. Press
DC OUTPUT
to accept the displayed settings, or
FUNCTION
to abort and proceed to
the next function.
NOTE: Until both units are configured properly, the displays will cycle as follows: status display
will flash
E241
(hardware error), then
DC VOLTS,
status display
and
DC AMPERES
flash
x
OF
y
where
x
= unit number and
y
= total number of units, the status display
flashes the type of connection
SERI
(series) or
PARA
(parallel).
3.2.10.3 OPERATING THE MASTER/SLAVE CONFIGURATION
Once the master is configured, it searches for the slave specified. Until the slave is set up prop-
erly, the master status display will cycle as follows: status display will flash
E241
(hardware
error), then
DC VOLTS,
status display
and
DC AMPERES
flash
x
OF
y
where
x
= unit number
and
y
= total number of units, the status display flashes the type of connection
SERI
(series) or
PARA
(parallel). When the slave is found, the status display of the slave reads
SLVE
and the
DC
VOLTS
and
DC AMPERES
displays on the slave go blank. For the master/slave combination to
work properly the number of slave units specified in the master (PAR. 3.2.10.1, step 5) must be
found.
When the slave has been found, the master proceeds with the normal turn-on sequence and the
unit proceeds to
SET
mode. The master front panel readouts show the total values for set point,
voltage and current readback, virtual model (the virtual model and protection settings of the
slave are automatically programmed to be the same as the master) and protection settings for
the master/slave configuration. All controls on the slave are disabled. The parallel or series
combination is controlled from the master using either the front panel, SCPI commands, or ana-
log control.
Содержание KLP SERIES
Страница 2: ......
Страница 6: ......
Страница 14: ...viii KLP073008 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 20: ...1 6 KLP 073008 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 21: ...KLP 073008 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ......
Страница 40: ......
Страница 86: ......