68
TK-5710
(
B
)
/5710H
(
B
)
ADJUSTMENT
6. Sensitivity
1) CH-Sig:1-1
SSG
Rear
ANT
Check
12dB SINAD or more
Check
SSG output:-117dBm(0.32
µ
V) AF VTVM
panel
EXT.SP
•Wide
(MOD:1kHz/±3kHz)
Oscilloscope
2) CH-Sig:2-1
3) CH-Sig:3-1
•Narrow
4) CH-Sig:1-1
SSG output:-117dBm(0.32
µ
V)
(MOD:1kHz/±1.5kHz)
5) CH-Sig:2-1
6) CH-Sig:3-1
7. Squelch
1) Adj item:[W SQOW]
Front
[PF5]
After input
After adjusting SQL,
(Threshold)
Adjust:[***]
panel
signal from SSG, check SQL open/close.
adjust
2) Adj item:[WL SQOW]
t
press [PF5] key.
[Panel test mode]
•Wide
[WC SQOW]
t
[WH SQOW]
That numeric
1) CH-Sig:1-1
Adjust:[***]
will be stored
SSG 12dB SINAD or
SSG output:12dB SINAD level -3dB
in memory.
less:Open
(MOD:1kHz/±3kHz)
SSG -130dBm(0.07
µ
V):Close
2) CH-Sig:2-1
SSG 12dB SINAD or
less:Open
SSG -130dBm(0.07
µ
V):Close
3) CH-Sig:3-1
SSG 12dB SINAD or
less:Open
SSG -130dBm(0.07
µ
V):Close
•Narrow
3) Adj item:[N SQON]
After adjusting SQL,
Adjust:[***]
check SQL open/Close.
SSG output:12dB SINAD level -3dB
[Panel test mode]
(MOD:1kHz/±1.5kHz)
1) CH-Sig:1-1
SSG 12dB SINAD or
less:Open
SSG -130dBm(0.07
µ
V):Close
2) CH-Sig:2-1
SSG 12dB SINAD or
less:Open
SSG -130dBm(0.07
µ
V):Close
3) CH-Sig:2-1
SSG 12dB SINAD or
less:Open
SSG -130dBm(0.07
µ
V):Close
Measurement
Adjustment
Item
Condition
Test-
Unit
Terminal
Unit
Parts
Method
Specifications/Remarks
equipment