63
TK-5710
(
B
)
/5710H
(
B
)
ADJUSTMENT
1. Frequency
1) Adj item:[W TXF]
f.counter
Rear
ANT
Front
[PF3],
Center frequency Note:After replacing
adjust
Adjust:[***]
panel
panel
[PF4]
±50Hz
the VCXO (X200) align
PTT:ON
frequency.
Press [PF5] to store the adjust-
ment value after adjustment.
2. Max
[Panel test mode]
Power
Final
VR1
55W
±2W
power
1) CH-Sig:1-1
meter
adjust
PTT:ON
Ammeter
•TK-5710
•TK-5710H
1) CH-Sig:3-1
118W
±2W
PTT:ON
3. High power
[Panel tuning mode]
Front
[PF3],
50W
±1W
adjust
1) Adj item:[W HPW]
panel
[PF4]
12A or less
Adjust:[***]
•TK-5710
2) Adj item:[WL HPW]
t
[WLC HPW]
t
[WC HPW]
t
[WCH HPW]
t
[WH HPW]
•TK-5710H
Adjust:[***]
110W
±2W
PTT:ON
25A or less
Press [PF5] to store the adjust-
ment value after adjustment.
4. Low power 1) Adj item:[W LPW]
5.0W
±0.5W
adjust
Adjust:[***]
5A or less
•TK-5710
2) Adj item:[WL LPW]
t
[WLC LPW]
t
[WC LPW]
t
[WCH LPW]
t
[WH LPW]
Adjust:[***]
•TK-5710H
PTT:ON
50W
±1W
Press [PF5] to store the adjust-
12A or less
ment value after adjustment.
5. DQT balance 1) Adj item:[W BALW]
Deviation
Rear
ANT
Front
[PF3],
Make the
adjust
Adjust:[***]
meter
panel
panel
[PF4]
demodulation
•Wide
Deviation meter filter
Oscilloscope
waves into
LPF:3kHz
AG
Front
MIC jack
square waves.
HPF:OFF
AF VTVM
panel
2) Adj item:[WL BALW]
t
[WLC BALW]
t
[WC BALW]
t
[WCH BALW]
t
[WH BALW]
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
•Narrow
3) Adj item:[N BALN]
Adjust:[***]
4) Adj item:[NL BALN]
t
[NLC BALN]
t
[NC BALN]
t
[NCH BALN]
t
[NH BALN]
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
Measurement
Adjustment
Item
Condition
Test-
Unit
Terminal
Unit
Parts
Method
Specifications/Remarks
equipment
Transmitter Section