Kendrion Kuhnke Automation GmbH
CAN Master/Slave
441
17 May 2021
Index
Name
Type
Default
Min Max
Access
7507
RxData7
UINT64
RO P
7508
RxData8
UINT64
RO P
7509
RxData9
UINT64
RO P
750A
RxData10
UINT64
RO P
750B
RxData11
UINT64
RO P
[750C]
RxData12
UINT64
RO P
[750D]
RxData13
UINT64
RO P
750E
RxData14
UINT64
RO P
F) 750.
RxData15
UINT64
RO P
7510
RxData16
UINT64
RO P
7511
RxData17
UINT64
RO P
7512
RxData18
UINT64
RO P
7513
RxData19
UINT64
RO P
Technical Data
CAN Master/Slave ......................................... Electrically insulated
Baud rate ....................................................... 100,125, 250, 500 and 1000 kbit/s
Payload data .................................................. 9 frames of max. 8 bytes In/Out per EtherCAT cycle
IO connection................................................. 18-pin, male
Controller ....................................................... ASIC ET1200
E-bus connector ............................................ 10-pole system plug in side wall
Terminating module ....................................... not required
Power supply ................................................. Via E-bus
E-bus load ...................................................... Max. 330 mA
Part no. .......................................................... 694 455 06
Approval .........................................................