Analogue interface configuration
– Analogue inputs
Object overview
Slot
Object
Subindex
Explanation
AI0
01
Is assigned automatically via the module
AI1
02
AI2
03
AI3
04
AI0
01
Scaling of the analogue input values by specifying
interpolation points. To output the scaled values, add
object 0x7130 AIInputPV the object to the mapping
AI1
02
AI2
03
AI3
04
AI0
01
Scaling of the analogue input values by setting the scaling
factor and offset. To output the scaled values, add object
0x7130 AIInputPV the object to the mapping
AI1
02
AI2
03
AI3
04
AI0
01
Object for output of the scaled analogue values
AI1
02
AI2
03
AI3
04
AI0
01, 05
Object for filtering the analogue input values
Subindex 01…04 Low pass filter
Subindex 05…08 Notch Filter
AI1
02, 06
AI2
03, 07
AI3
04, 08
AI0
01
Object for setting the PT1 filter time in [ms]
AI1
02
AI2
03
AI3
04
AI0
01
Object for
AI1
02
AI2
03
AI3
04