HW 1/17/05
Rev B
Page 1 of 2
6220 Programmable Current Source
SOURCE SPECIFICATIONS
Range
(+5% over range)
Accuracy
(1 Year)
23
°
C
±
5
°
C
±
(%rdg. + amps)
Programming
Resolution
Temperature
Coefficient/
°
C
0
°
-18
°
C& 28
°
-50
°
C
Typical Noise
(peak-peak)
/RMS
3,4,5
0.1Hz-10Hz
Settling Time
1,2
(1% of final value)
2nA
0.4% + 2pA
100fA
0.02% + 200fA
400/80fA
100
μ
s
20nA
0.3% + 10pA
1pA
0.02% + 200fA
4/0.8pA
100
μ
s
200nA
0.3% + 100pA
10pA
0.02% + 2pA
20/4pA
100
μ
s
2
μ
A
0.1% + 1nA
100pA
0.01% + 20pA
200/40pA
100
μ
s
20
μ
A
0.05% + 10nA
1nA
0.005% + 200pA
2/0.4nA
100
μ
s
200
μ
A
0.05% + 100nA
10nA
0.005% + 2nA
20/4nA
100
μ
s
2mA
0.05% + 1
μ
A
100nA
0.005% + 20nA
200/40nA
100
μ
s
20mA
0.05% + 10
μ
A
1
μ
A
0.005% + 200nA
2/0.4
μ
A
100
μ
s
100mA
0.1% + 50
μ
A 10
μ
A
0.01% + 2
μ
A 10/2
μ
A 100
μ
s
ADDITIONAL SOURCE SPECIFICATIONS
OUTPUT RESISTANCE:
>10
14
Ω
. (2nA/20nA range)
OUTPUT CAPACITANCE:
<10pF, <100pF Filter ON. (2nA/20nA
range)
LOAD IMPEDANCE:
Stable into 100
μ
H typical.
CURRENT REGULATION:
Line:
<0.01% of range.
Load:
<0.01% of range.
VOLTAGE LIMIT (Compliance):
Bipolar voltage limit set with
single value. 0.1V to 105V in 0.01V programmable steps.
Accuracy for 0.1V to 20V: 0.1% +20mV, accuracy for 20V to
105V: 0.1% + 100mV
MAX. OUTPUT POWER:
11W, four quadrant source or sink
operation.
GUARD OUTPUT:
Maximum Load Capacitance:
10nF.
Maximum Load Current:
1mA for rated accuracy.
Accuracy:
±
1mV for output currents <2mA. (excluding output lead
voltage drop).
PROGRAM MEMORY:
(offers point-by-point control and
triggering, e.g. Sweeps)
Number of Locations:
64K.
EXTERNAL TRIGGER:
TTL-compatible EXTERNAL TRIGGER
INPUT and OUTPUT.
Max Trigger Rate:
1000/s.
6220 – 2182 MEASUREMENT FUNCTIONS
DUT RESISTANCE:
Up to 1G
Ω
(1 nSiemen).
DELTA MODE RESISTANCE MEASUREMENTS and
DIFFERENTIAL CONDUCTANCE:
Controls Keithley Model
2182A Nanovoltmeter at up to 24Hz reversal rate (2182 at up to
12Hz).
Source Notes
1 Settling times are specified into a resistive load, with a maximum resistance
equal to 2V / I
fullscale of range
.
See manual for other load conditions.
2 Settling times to 0.1% of final value are typically <2x of 1% settling times.
3 Noise current into <100
Ω
.
4 RMS Noise 10Hz-20MHz (2nA – 20mA Range) Less than 1mVrms, 5mVp-p
(into 50
Ω
load).
5 Typical values are non-warranted, apply at 23
°
C, represent the 50
th
percentile,
and are provided solely as useful information.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Содержание 6220
Страница 16: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Страница 24: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Страница 403: ...A Specifications Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Страница 453: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...