2 2 8
0/1/2
0
Needle cooling output power set up
(0: 1: running action, higher than
the 22A parameter setspeed when the action, 2: cut the line after the
end of 229,the movement parameter setting time)
2 2 9
1 - 2550
2500
Needle cooling time delay
2 2 A
200 - 6000
200
Needle cooling start speed
2 2 B
1 - 20
2
AS-61 series double needle machine,automatic corner pin
number
2 2 C
0/1
2
Pressure foot work mode of the AS-61 series: 0: not with
thepresser foot, tacking, alternating quantity
association; 1: andfoot pressure, sewing, alternating quantity
association
。
2 2 D
0
~
359
0
Target angle angle (angle of complement needle needle)
2 2 E
0/1
0
AS-61 series double needle machine automatic
angleenergy-saving mode switch
0:off
;
1:on
2 3 0
0
/
1
0
Foot lifting control mode
0: Push button jog switch:
1: Valid when button is pushed;
Mode
selection
2 3 1
0
/
1
0
Auto test mode selection:
0: With certain stitch number
1: With certain time
2 3 2
0
~
1000
300
Safety alarm confirming time ms (for flat sewing machine safety
tilting switch and overlock sewing machine safety knife protection
switch are same, use the same solution)
2 3 3
0
~
1000
50
Safety switch recover confirm time ms
2 3 4
0
/
1
0
Motor resolving direction:
1: C.C.W
0: C.W.
22