3
、
the parameter settings are required to ensure that
(parameter 134) < (parameter 135) < (parameter 136) < (parameter 137) < (parameter
138) < (parameter 139)
4
、
an be used as the parameter's value through the pedal real-time monitoring of 025
parameters at different positions of the monitoring mode sampling numerical. Adjusting the
corresponding parameters, presser foot and step on or after step action position change. As
on the great distance machine is not running, may be appropriate
to reduce the 137 parameters (not less than to the location parameters in 136), can improve
the sensitivity of feet; if the machine is too sensitive, touch the pedal machines began to
work, it may be appropriate to increase the 137 parameters; if it is not easy to fill needle, a
little feet, speed quickly improve the cause forward multi needle, may be appropriate to
increase or decrease the 138 parameters of 137 parameters (i.e. adding feet pedal speed
range), can also be appropriate to reduce
the initial seam speed (100).
Fig. 4-1 pedal movement of each position parameter
33