3 System parameter setting
3.1 Technician mode
1
、
Press
key and
key can modify the technician parameter table.
2
、
The LCD will display
.Type the password for the technician, the initial password is 0 0
0 0
,
press the corresponding
key and the
key can change the password value;
3
、
Press
key
,
If the password is correct, enter into the technician parameter setting mode,shown
,
4
、
Press the corresponding
key and
key or
key and
key, select the
parameter and change the corresponding parameter.
5
、
Press
key, exit parameter setting mode, return to sewing mode.
NO.
Range
Default
Description
Comment
1 0 0
100~800
200
Start sewing speed
Speed
1 0 1
200~5000
3500
Maximum sewing speed
1 0 2
200~5000
3000
Maximum constant sewing speed
1 0 3
200~5000
3000
Maximum manual back tacking speed
1 0 4
100~800
200
Stitch compensation speed
1 0 5
100~500
250
Trimming speed
1 0 6
0
/
1
0
Soft start mode setup:
0
:
Soft start only after trimming
1
:
Soft start after both trimming and stop
1 0 7
1~9
2
Soft start stitch number
1 0 8
100~800
200
Soft start speed
10