manualshive.com logo in svg
background image

 

ISTRUZIONI D’USO – USE INSTRUCTIONS – 

GEBRAUCHSANLEITUNGMODE D’EMPLOI - 

INSTRUCCIONES PARA EL USO - 

Οδηγίες - 

INSTRUÇÕES DE USO 

IST-USO-0906007 

Rev. N. 6 del 15/10/2021 

IDP107  

Pg. 5 di 16

 

 

ENGLISH 

CAUTION 

In  order  to  use  the  face  mask  safely  and  avoid  risks  it  is  fundamental  that  these 
instructions  and  those  relative  to  the  filters  be  clearly  understood.  Particular 
attention is to be paid to warnings, cautions and use limitations.  

IMPORTANT: 
1. 

Before  using  the  face mask be sure to understand fully and adhere to all the 
instructions herein. 

2. 

Use the face mask only for the purposes stated.  

3. 

Use only original KASCO spare parts for the maintenance of this face mask. 

4. 

Product  responsibility  for  the  correct  functioning  of  this  face  mask  is 
irrevocably transferred to the owner/end user if: 

-  The  face  mask  is  maintained  or  repaired  by  personnel  or  by  service 
centres not employed or authorised by Kasco. 
-  The  face  mask  is  used  in  a  manner  or  for  uses  not  conforming  to  its 
intended use as specified in these instructions. 

1. APPLICATION

 

1.1 Description

 

Negative  pressure  full  face  mask  with  normalized  threaded  connection  in 
accordance  with  UNI  EN  148-1:  2018,  two  inhalation  valves  of  the  internal  mask 
and an exhalation valve. Harness with five tie rods fixed on the perimeter edge of 
the  visual  screen.  The  materials  of  which  it  is  composed  allow  its  use  in 
atmospheres considered at risk of explosion. To provide respiratory protection, the 
mask must be combined with a filter manufactured by Kasco. 
It  is  possible  to  use  the  mask  as  a  component  of  an  electric  respirator.  (See 
respiratory composition and related instructions for use in this regard). 

1.1.1 Venus1 

The sealing body is designed to conform all face shapes in one size. Upon request, 
a protective film can be applied to the polycarbonate visor. 

1.1.2 Zenith1 

Full face mask with black silicone body and panoramic polycarbonate visor. 
The device is available in three sizes: 
- Size S (small), described above 
- Size M (medium), with five tie rods harness fixed on special wings obtained from 
the sealing edge 
- Size L (large), with harness like size M 
The 1005009 ZENITH1 model can be supplied in the following variants: 

1005009‐X 

 
 
 
 
 
 
 
From the combination of the variants, 3 codes are obtained: 
1005009-S; 
1005009-M; 
1005009 

 L. 

1.2 Function

 

Breathable,  filtered,  air  passes  through  the  inhalation  valves  to  the  inside  of  the 
visor. 
The  filtered  air  flows  over  the  visor  minimising  visor  misting  then  passes  through 
check valves to the inner mask. 
Exhaled air is expelled through the exhalation valve. 

1.3 Reference standards

 

The  full  face  mask  is  designed  to  and  complies  with  the  requirements  of  the 
technical  standard  EN136:1998  and  meets  the  performance  requirements  laid 
down therein.

 

1.4 Use 

The  full  face  mask,  with  the  limitations  specified  at  clause  1.6,  may  be  used 
exclusively for respiratory protection against gases and/or liquid and solid aerosols. 
See filter/cartridge instructions for permissible concentrations. 

1.5 Protection factor

 

The full face mask protection factor is determined by; the face mask seal, the filter 
protection class, the state of conservation and maintenance of the face mask.  

1.6 Use Limitations

 

Do not use the face mask if: 

 

the nature and concentration of the contaminant present in the atmosphere is 
not known.  

 

the  concentration  of  the  contaminant  in  the  atmosphere  exceeds  the  filter 
protection class limits (See filter use instructions).  

 

the type of contaminant is not provided for by the type of filter.  

 

the oxygen concentration in the atmosphere is lower than 17% in volume.  

 

in  closed  work  locations  (ex.  tanks,  duct,  silos  underground  locations)  and 
fresh air delivery systems are not available. 

Use 

limitations for PAPR’s may be found in relative Use Instructions

1.7 Cautions

 

The full face mask is to be used only by workers: 

 

who have been trained on the use of respiratory protective devices.  

 

who do not have respiratory problems or an impaired sense of smell. 

 

who do not have sideburns, a beard and/or a moustache as these will hinder a 
good face mask seal. 

 

Who do not use eyewear. 

Do not use the face mask: 

 

if it has not been thoroughly cleaned and disinfected. 

 

if it has failed the face seal tightness test. 

 

if there is a doubt that parts are missing and/or one or more parts look 
defective. 

 

if there is no evidence of period maintenance.  

 

with oxygen cylinders or in oxygen enriched atmospheres.  

Return to fresh, clean air immediately and remove face mask in the case: 

 

of uncommon smell or taste. 

 

of unjustified or sudden irritation of the nose or throat .  

 

of inhaled air becoming extremely hot.  

 

dizziness, nausea or headaches occur. 

2. CLASSIFICATION

 

Full face mask for special uses : CLASS 3 

3. INSPECTION 

Before using the face mask make sure that:  

 

it is clean and disinfected and does not present evident defects.  

 

there are no parts missing. 

 

the inhalation and exhalation valves have been properly inserted. 

 

the filter sealing gasket is properly housed.  

4. DONNING AND FITTING 
4.1  Donning 

 

Don the face mask before entering the contaminated area. 

 

Release the strap buckles and pull the straps through as far as they will go.  

 

Spread out the two lateral straps. 

 

Slip carrying strap around neck and position chin in the chin support.  

 

Position face mask against the face, pass the harness over the head and pull 
straps back in the following sequence: cheek straps, temple straps, forehead 
strap.  

The ideal position of the mask against the face is obtained when, without excessive 
pulling, the mask fits snugly and the seal provides an even pressure distribution 
over the entire area in contact with the face. 

4.2 Seal Tightness test 

After having donned the mask and obtained a good fit press the palm of your hand 
over the threaded connector and inhale slightly in order to generate negative 
pressure. Hold your breath for a second and if no air leaks are detected a good fit 
has been obtained. If air leaks are detected pull straps tighter and repeat test. If 
leakage persists reposition the face mask as described at point 4.1  and 4.2 and 
repeat seal tightness test. 

4.3 Exhalation valve test 

Cover the threaded connector with the palm of your hand and exhale. Exhaled air 
should flow out of the mask without appreciable resistance.  

5 USE 
5.1 Aplication: 

Some of the uses for which the protective device, equipped with proper filter, has 
been designed: 
• agriculture: cleaning of stables, sheepfolds and chicken coops. Grain handling 
and processing; mixing / spraying: pesticides, fungicides, herbicides; Spraying and 
weeding with operating machine; pest control treatments; 
• Asbestos reclamation and abatement: removal of untreated and dry asbestos 
coverings; asbestos handling and disposal; glass production activities, means of 
transport gaskets. 
• Chemistry and pharmaceuticals: powder formulation, chemical formulations and 
special pastes; biological risk and infectious diseases. 
• Construction, building and renovation: Concrete, cement, stone, masonry and 
plaster handling / cutting / smoothing / grinding /drilling; Surface painting and 
coating; restructuring; controlled demolition. 
• Waste management: Handling and disposal of waste; Decontamination; Waste 
removal. 
• Metal working: Machining and scraping. 
• Woodworking: cutting / planing / drilling; scraping and sanding. 

 Glass fibers and minerals processing: Mineral tile laying; Spraying operations; 

Mineral extractions and marble work. 

 

Maintenance: Disinfection and cleaning with acids, aldehydes. 

 

 

Spray painting and sandblasting: Powder coating; Spraying / latex painting; Wet 

or dry sandblasting.

 

5.2 Instructions: 

Screw  on  proper  filters  only  after  the  mask  has  been  tested  and  has  passed  the 
seal tightness test. 
The use of the mask is determined by the type and model of filter used. Follow the 
filter  Use  Instructions  packed  with  filters  and,  in  any  case,  leave  the  area 
immediately if smell or taste of the contaminant is detected or if breathing becomes 
more difficult. 
For use in extreme conditions adhere to the following cautions: 

 

In the case of extremely low temperatures treat visor with an anti-misting liquid 
(compatible  with  the  eyes  and  skin  and  which  will  not  damage  rubber  and 
plastic) and regularly check the exhalation valve diaphragm as it could harden 
resulting in possible leakage.  

 

In the case of extremely high temperatures leave the area immediately should 
vision become obscured. 

Code/part number: 
1005009

 

Size: 

= Small 

M = 

Medium 

= Large

 

 

Содержание VENUS1

Страница 1: ...USO USE INSTRUCTIONS GEBRAUCHSANLEITUNG MODE D EMPLOI INSTRUCCIONES PARA EL USO INSTRU ES DE USO VENUS1 1005006 ZENITH1 1005009 S M L MASCHERA A PIENO FACCIALE FULL FACE MASK VOLLGESICHTS MASKE MASQUE...

Страница 2: ...CIONES PARA EL USO INSTRU ES DE USO IST USO 0906007 Rev N 6 del 15 10 2021 IDP107 Pg 2 di 16 KASCO SRL Via Romania 12 42124 Reggio Emilia Italia tel 39 0522 308232 fax 39 0522 939803 e mail kasco kasc...

Страница 3: ...nare immediatamente all aperto e all aria pulita e togliere la maschera se si sentono sapori od odori si sente ingiustificata e improvvisa irritazione di naso o gola l aria inalata diventa estremament...

Страница 4: ...chera interna Controllare il disco valvola 2 1 Controllare soltanto a caso se le maschere sono imballate ermeticamente 2 I dischi valvola sono prodotti in silicone anti et Rimpiazzare solo se danneggi...

Страница 5: ...the face mask if it has not been thoroughly cleaned and disinfected if it has failed the face seal tightness test if there is a doubt that parts are missing and or one or more parts look defective if...

Страница 6: ...e The efficiency of the full face mask depends on the maintenance carried out and the periodic replacement of some of its parts as detailed in the table below Part Work to be carried Frequency out aft...

Страница 7: ...f in folgenden F llen nicht verwendet werden Die Maske wurde nicht sorgf ltig gereinigt und desinfiziert Die Maskendichtpr fung ergab unzureichende Ergebnisse Es bestehen Zweifel dar ber ob alle Maske...

Страница 8: ...itabst nde ab Bauteil Durchzuf hrende Arbeiten H ufigkeit nach jedem Gebrauch halbj h rlich j hrlich Maske komplett Reinigen Desinfizieren Funktionst chtigkeit und auf Lecks kontrollieren 1 3 3 Verbin...

Страница 9: ...it a donn un r sultat n gatif en cas de doute sur d ventuelles pi ces manquantes et ou si une ou plusieurs pi ces pr sentent un d faut s il n a pas t entretenu r guli rement avec de l oxyg ne ou dans...

Страница 10: ...necteur masque Contr ler la bague d tanch it Changer la bague d tanch it 1 Soupape d expiration Contr ler le disque de la soupape Changer le disque de la soupape 1 Soupape d inspiration Contr ler le d...

Страница 11: ...prueba de estanqueidad ha dado resultado negativo si existen dudas en relaci n con piezas que puedan faltar o que tengan defectos si no existe la certidumbre de que se hayan efectuado todas las operac...

Страница 12: ...uir el anillo de retenci n 1 V lvula de expulsi n Controlar el disco de la v lvula Sustituir el disco de la v lvula 1 V lvula de inspiraci n Controlar el disco de la v lvula Sustituir el disco de la v...

Страница 13: ...IST USO 0906007 Rev N 6 del 15 10 2021 IDP107 Pg 13 di 16 1 2 3 KASCO 4 asco asco 1 1 1 UNI EN 148 1 2018 Kasco 1 1 1 Venus1 1 1 2 Zenith1 S M L M 1005009 ZENITH1 1005009 X 3 1005009 S 1005009 M 1005...

Страница 14: ...y 6 50 C 6 1 COVID19 5443 20 02 2020 1 0 1 0 5 62 71 0 5 10 50 C 7 7 1 7 2 7 3 8 8 1 o ring 60 o ring 8 2 8 1 o ring 8 3 6 1 3 3 1 1 2 1 2 1 2 3 KASCO 8 4 OR KASCO KASCO 9 1 4 5 6 7 8 10 9 12 4 2 11 2...

Страница 15: ...ltado do teste de estanqueidade for negativo se houver d vidas de que faltam partes e ou uma ou mais pe as apresentem defeitos se n o houver a evid ncia de uma manuten o peri dica com oxig nio ou para...

Страница 16: ...lar o funcionamento correcto e a aus ncia de perdas 1 3 3 Conector da m scara Controlar o anel de veda o Substituir o anel de veda o 1 V lvulas de exala o Controlar o disco da v lvula Substituir o dis...

Отзывы: