![Kampmann KaDeck Series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/kampmann/kadeck-series/kadeck-series_installation-and-operating-instructions-manual_3354081024.webp)
24
3.26
KaDeck
Versatile air conditioning for offices and administration buildings
Installation and operating instructions
Vorderansicht
Vorderansicht
Vorderansicht
Vorderansicht
Ansicht von unten
Ansicht von unten
Ansichten von unten
Ansichten von unten
Under-ceiling installation
Drill the holes for the fixing dowels into the concrete ceiling slab.
Then fix the dowels and threaded rods in place.
Mark the drill hole positions on the ceiling (refer to the under-
ceiling drilling template (one-sided: 340 mm x 1029 mm / two-
sided: 470 mm x 1029 mm)
Drill, position the threaded rods, fit the nuts and washers.
Fit the connection covers as per the diagram.
(with 1-sided discharge, the separating plate supplied must be
fitted between the connecting panels)
Suspend the unit, tighten and lock the nuts.
Connect up the heating and electrics.
Optional: Connect the condensation side.
Optional: Fit and connect the primary air spigot.
Installation within a suspended ceiling
With ceiling structures with inlay panels, they are largely removed
around the KaDeck.
Bei einer festen Gipskartondecke wird ein entsprechender Ausschnitt
nach nebenstehenden Maßen erstellt.
With a rigid plasterboard ceiling, a corresponding cut-out is
produced in line with the adjacent dimensions.
Fit the suspension brackets on the KaDeck.
Mark the drill positions on the ceiling
(one-sided: 490mm x 1050mm / two-sided: 620mm x 1050mm)
Drill, position the threaded rods, fit the nuts and washers.
Suspend the unit so that the frame of the unit is positioned just
under the suspended ceiling.
Adjust the unit into the correct position and lock in place by
tightening the nuts upwards.
Connect up the heating and electrics.
Optional: Connect the condensation side.
Optional: Fit and connect
the primary air spigot.
6.3. Suspending the unit
Important: Only ask 2 people to suspend the unit due to heavy loads!
Drilling positions with under-ceiling
installation
Fitting the connection covers
Unit positioned in the suspended ceiling
Vorderansicht
Vorderansicht
Vorderansicht
Vorderansicht
Ansicht von unten
Ansicht von unten
Ansichten von unten
Ansichten von unten
Front view
Front view
Front view
Front view
View from below
View from below
View from below
View from below
* Dimensions for drilling positions with suspended ceiling installation
Under-ceiling units
Suspended ceiling units