3-15
Gas Console Output Connections
Perform the following steps to connect the automatic gas console outputs to the torch gas
hoses.
Note: When making hose connections, only tighten the brass
fittings enough to make gas seals. The fittings are
subject to damage if over tightened.
Preflow Outlet
•
Connect the preflow hose to the Preflow Out port as shown. Note that the
Preflow Out port has left hand threads.
Plasma Outlet
•
Connect the plasma hose to the Plasma Out port as shown. Note that the Plasma
Out port has right hand threads.
Shield Outlet
•
Connect the shield hose to the Shield Out port as shown. Note that the Shield Out
port has right hand threads.
Postflow Outlet
•
Connect the postflow hose to the Postflow Out port as shown. Note that the
Postflow Out port has right hand threads.
Figure 3-7 Gas Console Output Connections