Full digital ultrasonic diagnostic instruments (Vet) User’s Manual V2.00
15
6.9.2 Open image
Open image in the main unit
1. Freeze the image;
2. Continuously press
key twice, a “Read” prompt appears on lower right corner of the screen;
3. Press direction keys
to select the image code need to be read out in the “LOCAL”, such as
choose “003*”;
4. Press
key to appear “Wait” prompt. After the prompt disappear, the image stored in frame “003*”
is read out;
5. Press
key to quit reading status and press
key to return to real-time status.
Open image in the U disk
1. Plug U disk;
2. Freeze the image;
3. Continuously press
key twice, a “Read” prompt appears on lower right corner of the screen;
4. Press direction keys
to select the image code need to be read out in the U disk, such as choose
“004*”;
5. Press
key to appear “Wait” prompt. After the prompt disappear, the image stored in frame “004*”
is read out;
6. Press
key to quit reading status and press
key to return to real-time status.
Explanation:
1. When reading images, it must choose the image code with “*”.
2. If you want to read out the images within the folder identified by number (ID) under the U disk,
must input ID first before reading, then do as the above steps; if did not enter the number (ID),
it would default to read out the images in the “USER” folder under the U disk.
3. If has read out the images in the U disk, also would like to re-read the local image, must
press
key to exit this reading status, then press
key to choose “LOCAL”, and vice versa.
6.10 Single dump and mass dump
6.10.1 Single dump
From main unit to U disk
1. Read out the image in the main unit, “Img” with highlight status is displayed on lower right corner of
the screen;
2. Press
key, a “Dump” prompt appears on lower right corner of the screen;
3. Press direction keys
to select the image saving code in the U disk, such as choose “005”;
4. Press
key, “Dump” prompt disappears, until the “Dump” re-appears, the current image can be
dumped in the frame for coded “005”. The dumped image code is preceded with asterisk “*”;
5. Press
key to quit dumping status and press
key to return to real-time status.
From U disk to main unit
1. Enter the number (ID), after completed it, exit the enter status;
2. Read out the image in the U disk, “Img” with highlight status is displayed on lower right corner of the
screen;
3. Press
key, a “Dump” prompt appears on lower right corner of the screen;
4. Press direction keys
to select the image saving code in the “LOCAL”, such as choose “006”;
5. Press
key, “Dump” prompt disappears, until the “Dump” re-appears, the current image can be
dumped in the frame for coded “006”. The dumped image code is preceded with asterisk “*”;