Kaden Installation Manual |
25
7. Refrigerant Piping
Connection
Note on pipe length
The length of refrigerant piping will affect the performance and energy efficiency of the unit. Nominal efficiency is tested on units with
a pipe length of 5 meters (16.5ft).
Refer to the table below for specifications on the maximum length and drop height of piping.
Maximum length and drop height of refrigerant piping per unit model
Model
Capacity (kW)
Max. Length (m)
Max. Height Difference (m)
KS09
2.6kW
25
10
KS12
3.5kW
25
10
KS18
5.0kW
30
20
KS24
7.0kW
50
25
KS28
8.0kW
50
25
Connection instructions –
refrigerant piping
Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to cut and
flare them properly. This will ensure efficient operation and
minimize the need for future maintenance. Remember to
always use a tuber cutter.
1. Measure the distance between the indoor and outdoor units.
2. Using a pipe cutter, cut the pipe a little longer than the
measured distance.
3. Make sure that the pipe is cut at a perfect 90° angle.
Refer to Fig. 5.1 for bad cut examples.
Oblique
Rough
Warped
90°
Fig. 5.1
J3387_Kaden_Installer_Manual_050917.indd 25
5/09/2017 9:08 AM
Содержание KS09
Страница 2: ...J3387_Kaden_Installer_Manual_050917 indd 2 5 09 2017 9 07 AM...
Страница 34: ...34 Kaden Installation Manual Notes J3387_Kaden_Installer_Manual_050917 indd 34 5 09 2017 9 08 AM...
Страница 35: ...Kaden Installation Manual 35 Notes J3387_Kaden_Installer_Manual_050917 indd 35 5 09 2017 9 08 AM...
Страница 36: ...J3387_Kaden_Installer_Manual_050917 indd 36 5 09 2017 9 08 AM...