Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating sleeve attached
to the back of the unit. You must prepare the piping before
passing it through the hole in the wall. Refer to the
Refrigerant Piping Connection
section of this manual
for detailed instructions on pipe flaring and flare torque
requirements, technique, etc.
If refrigerant piping is already embedded in the wall,
do the following:
Step 1: Hook the indoor unit on the
mounting plate:
Keep in mind that the hooks on the mounting plate are smaller
than the holes on the back of the unit. If you find that you don’t
have ample room to connect embedded pipes to the indoor
unit, the unit can be adjusted left or right by about 30-50mm
(1.25-1.95in), depending on the model. (See Fig.3.4)
Fig. 3.3
Move to left or right
30-50mm
(1.2-1.95in)
30-50mm
(1.2-1.95in)
Fig. 3.4
Step 2: Prepare refrigerant piping:
1. Disassemble the louver:
2. Open and fix the position of the panel. Firstly, unscrew
the two screws showed in the picture below, then open
the panel, and fix the position of the panel by the latch
(see Fig.3.6).
Fig. 3.5
CAUTION
Be extremely careful not to dent or damage the piping
while bending them away from the unit. Any dents in
the piping will affect the unit’s performance.
Note on piping angle
Refrigerant piping can exit the indoor unit from four
different angles:
• Left-hand side
• Left rear
• Right-hand side
• Right rear
Refer to
Fig. 3.3
for details.
Fig. 3.3
Fig. 3.5
Fig. 3.4
J3387_Kaden_Installer_Manual_050917.indd 14
5/09/2017 9:08 AM
Содержание KS09
Страница 2: ...J3387_Kaden_Installer_Manual_050917 indd 2 5 09 2017 9 07 AM...
Страница 34: ...34 Kaden Installation Manual Notes J3387_Kaden_Installer_Manual_050917 indd 34 5 09 2017 9 08 AM...
Страница 35: ...Kaden Installation Manual 35 Notes J3387_Kaden_Installer_Manual_050917 indd 35 5 09 2017 9 08 AM...
Страница 36: ...J3387_Kaden_Installer_Manual_050917 indd 36 5 09 2017 9 08 AM...