1.7
Menu of the communication device
Note
:
In both cases, you now have access to
the communication device.
Here you can make settings that do not
directly affect the function of the inverter.
For
initial commissioning
, we recommend
calling up the following parameter:
-
Set up time zone
-
Set the country and grid type
identically for each connected
inverter. (Observe local grid
requirements!)
-
View the current values of the
customer's PV system in order to
detect any faults.
-
View the Modbus address.
Note:
After exiting the initial start-up, the
serial number-based password is required to
set further parameters. See chapter 4 on page
Fig. 18.
Communication device in the
local network
Fig. 19.
Communication device in the
customer WLAN network
1.8
Set up time zone
Note
: The time transmitted by the network is GMT time. You should now
adjust the time zone depending on the installation location.
This time is also used for the display in the "blueplanet web" portal.
1.
Select time zone.
2. Confirm selection with <OK>.
Note:
If there is no Internet available on the network, you have to make
the changeover to summer/wintertime manually.
»
Time zone set.
1.9
View available inverters
All inverters are connected via a communication device.
1. Select the desired <inverter> under <communication device>.
Note:
Up to 5 inverters can be connected to one communication device.
2.
Adjust parameters via <parameter settings>.
>> see chapter 4 on page 15 or Pos. 3
3. View feed-in values of the selected unit via <instantaneous values>. >>
Fig. 20.