7
B) User does not know the Master code:
1.
Insert mechanical override key, turn counterclockwise and hold so that lock is
in open position (cylindrical latch is retracted). Within 5 seconds, press # and
release the key (latch).
2. You have up to 5 seconds to push ‘#’ and release the override key. If 5-second
timeout is reached without pressing ‘#’, the lock continues its normal opera-
tion. As soon as the ‘#’ is pressed, the lock exits the current state. If timeout is
reached or if any other access state. If ‘#’ is pushed and reset button is release
within 5-second period, the lock goes in Reset Sequence State and the lock dis
plays the ‘Reset Sequence In Progress message by flashing Green and Red LED
alternatively once every second.
3. In this state, users have a 20-second period to enter the Master Code to per
form a hard reset. When the user does not know the master code, the user
must not enter anything during that 20 seconds delay. The Reset sequence in
progress message will be displayed on the LEDs.
4. When the 20 seconds delay will be exhausted, a 15 minutes wait period will
begin. During that state, any operation on the lock will be ignored (green LED
will not blink when pressing keys) and the Green and Red LED will blink once
a
minute.
5. After the 15 minutes delay has exhausted, the Reset sequence in progress mes-
sage will be displayed on the LEDs again for 20 seconds. During this period,
the user must enter the 1-2-3-4-5-6-7-8-# sequence and the lock will reset. If
the user fails to do so, the sequence will abort and the lock will resume normal
operation.
Hard reset sequence for E-Plex 3xxx Series:
A) User knows the Master code:
1.
Insert mechanical override key, turn to 3 o’clock position, press # and then turn
key back to 12 o’clock position within 5 seconds.
2. You have up to 5 seconds to push ‘#’ and then turn key back to 12 o’clock posi-
tion. If 5-second timeout is reached without pressing ‘#’, the lock continues its
normal operation. As soon as the ‘#’ is pressed, the lock exits the current state.
If timeout is reached or if any other key is pressed after the ‘#’ was pressed,
the lock exits the sequence and stays in access state. If ‘#’ is pushed and reset
button is released within 5-second period, the lock goes in Reset Sequence
State and the lock displays the ‘Reset Sequence In Progress’ message by flash-
ing Green and Red LED alternatively once every second.
3. In this state, users have a 20-second period to enter the Master Code to per
form a hard reset. If a bad Master Code is keyed-in, the lock exits the Reset
Sequence State and goes back in access state. If the correct Master Code is
entered within 20 seconds, the lock performs a hard reset and goes back in
unprogrammed state. When an incorrect Master Code is entered, the Tamper
Count decrements. After 4 unsuccessful attempts to Reset the lock with a bad
Master code, the lock goes in the Tamper Shutdown state for 30 seconds. It will
resume normal operations after this delay. If no master code is entered
during the 20 seconds delay, the lock will enter a 15 minute wait period assum-
ing the Master Code is unknown.
Содержание EX3600
Страница 1: ...Operations Manual E Plex Card based 36xx 37xx 56xx 57xx lock series ...
Страница 38: ...36 Notes Notes ...
Страница 39: ...37 Notes Notes ...