8
B) User does not know the Master code:
1.
Insert mechanical override key, turn to 3 o’clock position, press # and then turn
key back to 12 o’clock position within 5 seconds.
2. You have up to 5 seconds to push ‘#’ and then turn key back to 12 o’clock posi-
tion. If 5-second timeout is reached without pressing ‘#’, the lock continues its
normal operation. As soon as the ‘#’ is pressed, the lock exits the current state.
If timeout is reached or if any other key is pressed after the ‘#’ was pressed,
the lock exits the sequence and stays in access state. If ‘#’ is pushed and reset
button is release within 5-second period, the lock goes in Reset Sequence State
and the lock displays the ‘Reset Sequence In Progress message by flashing
Green and Red LED alternatively once every second.
3. In this state, users have a 20-second period to enter the Master Code to per
form a hard reset. When the user does not know the master code, the user
must not enter anything during that 20 seconds delay. The Reset sequence in
progress message will be displayed on the LEDs.
4. When the 20 seconds delay will be exhausted, a 15 minutes wait period will
begin. During that state, any operation on the lock will be ignored (green LED
will not blink when pressing keys) and the Green and Red LED will blink once
a
minute.
5. After the 15 minutes delay has exhausted, the Reset sequence in progress mes-
sage will be displayed on the LEDs again for 20 seconds. During this period, the
user must enter the 1-2-3-4-5-6-7-8-# sequence and the lock will reset. If the
user fails to do so, the sequence will abort and the lock will resume normal
operation.
Содержание EX3600
Страница 1: ...Operations Manual E Plex Card based 36xx 37xx 56xx 57xx lock series ...
Страница 38: ...36 Notes Notes ...
Страница 39: ...37 Notes Notes ...