18
PROCEDURE 3B - ADD / MODIFy A SERVICE USER CREDENTIAL
A Service User is any person who needs access to the lock for a limited time period in
order to perform a service, such as painting or repairs to the room or area. A Service
User’s access credential is always PIN only. Typically a Service user’s PIN can be valid
for either, one time use only (“one shot” entry), or from 1 through 96 hours expiry use.
Additionally, you can assign “super” Service users whose PINs will never expire until you
delete them from the lock.
Required User Level: Master, Manager
1. Put the lock into “LearnLok
TM
” Pushbutton Programming Mode ->
#
Master PIN (or Manager credential) #
2. Enter Command
102#
to add / modify a Service User Access PIN.
3. Enter the Service User ID location NNN followed by #,
NNN#
; we will use 125# for
example (Range = 001 to 300).
4.
(PIN only mode): After 102# 125# entry, enter the Service user’s PIN (we will use
7777 in this example) twice, the second time is for re-confirmation and finally
enter the expiry time -> either one shot (00), or 1 through 96 hours (01 through
96), or no expiry (99).
Example of Complete Entry for Service user ID=125 with one shot expiry:
102# 125# 7777# 7777# 00# # .
Example of Complete Entry for Service user ID=125 with expiry of 12 hours:
102# 125# 7777# 7777# 12# # .
Example of Complete Entry for Service user ID=125 with no expiry:
102# 125# 7777# 7777# 99# # .
Note: In all the above examples, the Service User’s Access PIN will work in that door
for the programmed period of the time the Service user enters her/his PIN the
first time.
PROCEDURE 4B - DELETE ACCESS USER CREDENTIALS
Access User credentials should be deleted from the lock if no longer needed since there
is no expiry. This frees this ID location to the assigned to another user. Credentials that
may be needed sometime in the future should be just de-activated rather than deleted
(see Procedure 13).
Required User Level: Master, Manager
1. Put the lock into “LearnLok
TM
”Pushbutton Programming Mode.
2. Enter Command
200#
to delete an Access User Credential whether it is card only
credential or PIN & card credential; you do not need this person’s card and/or the
PIN to delete.
3. Enter the Access User ID location
NNN#
, where
NNN
is the specific User ID loca-
tion from 001 to 300.
Enter a last # to indicate the end of programming.
Example of Complete Entry for user ID=023
200# 023# # .
Now this user’s credential will not work in the lock anymore. This allows you to
assign another user to this deleted User ID location if you wish.