5.3 Programming parameters for HCU
Page 94
Docu-No.: 0590020601-EN Rev. 1.6.0
5.3
Programming parameters for HCU
This table shows parameter number and description, which can be
entered in the section
for HCU loader control.
For a detailed
description of all parameters see manual 0290023601.
Param Number/ Param description
KSU
Param.
Min
Max
Step
Default
Actual
P1 – Load Timer
(Cycle 3)
Load
5 sec
300 sec
1 sec
20 sec
P2 – Clear Timer
(Cycle 4)
LineClr
0 sec
30 sec
1 sec
0 sec
P3 – Discharge Timer
(Cycle 6)
Disch
2 sec
90 sec
1 sec
10 sec
P4 – Filter Delay Timer
Fill Dly
1 sec
5 sec
0.1 sec
5 sec
P5 – Filter Pulse Timer
Fil Pul
0 sec
0.5 sec
0.1 sec
0.1 sec
P6 – Motor Timer
(Cycle 1
)
Motor
30 sec
1620
sec
30 sec
5 min
P7 – Load Delay Timer (
Cycle 2)
Ld Dly
0 sec
20 sec
1 sec
5 sec
P8 – Discharge Delay Timer
(Cycle 5)
Dis Dly
0 sec
20 sec
1 sec
5 sec
P9 – Input Filter: Receiver Proximity Sensor
In: Rec
0.1 sec
10 sec
0.1 sec
3 sec
P10 – Input Filter: Buffer Hopper Proximity Sensor
In: BuH
0.1 sec
10 sec
0.1 sec
3 sec
P11 – Input Filter: Supply Hopper Proximity Sensor
In: SuH
0.1 sec
10 sec
0.1 sec
1 sec
P12 – Input Filter: Remote Start
In: Strt
0.1 sec
10 sec
0.1 sec
0.5 sec
P13 – Input Filter: Remote Stop
In: Stop
0.1 sec
10 sec
0.1 sec
0.5 sec
P14 – Input Filter: Discharge Valve Switch
In: DisV
0.1 sec
10 sec
0.1 sec
1 sec
P15 – Input Filter: Filter Pressure Switch
In: FiPs
0.1 sec
10 sec
0.1 sec
1 sec
P16 – Input Filter: Discharge Request
In: DiRe
0.1 sec
10 sec
0.1 sec
1 sec
P17 – Input XOR Mask
Xor Msk
7F(dec12
7)
P18 – Oper M (Operating Mode)
1 = Self contained with discharge valve, 2 = Single
central with discharge valve, 3 = Self contained, 4 =
Single Central
Oper M
1
P19 – Clean Filter
0 = disables all cleaning, 1 = clean during discharge
cycle, 2 = clean during load cycle, 3 = clean during
both discharge and load cycles.
Clean M
1
P20 – Discharge Mode, 1 = Fill mode, 2 = LWF mode
Disch
1
P21 – Controller Address
HCUAdd
0x01
P22 – Controller Software Version
HCU SW
P23 – Supply Hopper Low Alarm Timer
Al ShLo
0 sec
600 sec
10 sec
0 disable
P24 – Differential Pressure High Alarm Timer
Al DPHi
0%
100%
1%
0 disable
P25 – Load Cycle Alarm Counter
Al Cycle
0 cycle
20 cycle
1 cycle
0 disable
P26 – Discharge Valve Alarm Timer
Al Valve
0 sec
15 sec
1 sec
10 sec
P27 – On/Off Counter
O/F Cnt
N/A
P28 – Run Time Counter
Run Cnt
N/A
P28 – Handheld display Software version
HSU SW
N/A
P63 – Digital input states
Dig In
N/A