Programming Reference
1.11System setup (only KSU-II/KCM).
Page 58
Docu-No.: 0590020601-EN Rev. 1.6.0
1.11
System setup (only KSU-II/KCM).
This menu programs the key communication functions for the KCM.
Note:
• Siemens 3694R protocol is not supported.
1.11.1
Communication sub-menu
This menu is only used with the KSU-II/KCM display and not available
for KSL, K-Vision or KSC.
Parameter
Definition
HOST PROT
Input of the desired communication protocol
Input range: Modbus, ALLEN BRAD AB-CIF, Siemens 3694R,
ProfibusDP, Modbus/TCP, DeviceNet, Ethernet/IP, ModbusPlus,
Profinet IO.
Default: None
HOST FILE
Select either a custom downloaded *.kgr file for data
communications or select a pre-loaded file (built-in). See manual
0590020611 for details.
Input range: Kgr File, Small, Full.
Default: Kgr File
IP
IP Adress
Only present when an Ethernet Host board is installed.
If the KGR file is used, this parameter is read-only.
NM
Net Mask
Only present when an Ethernet Host board is installed.
If the KGR file is used, this parameter is read-only.
GW
GateOnly present when an Ethernet Host board is installed.
If the KGR file is used, this parameter is read-only.
K-PORT1 PROT
Selects the function for K-Port1, Choices are: None, KSU, KSL,
KSC/K-Vision.
Default: KSU
BAUD RATE
Displays baud rate selections when K-Port1 is set to KSC/K-Vision
or if set to KSL and the service variable K10S_KCDR is <1>.
Choices are: 9600, 19200, 38400, 57600, 115200
K-PORT 2 PROT
Selects the function for K-Port2, Choices are: None, KSU, Modbus I-
O, KSC/K-Vision.
Default: KSU
Table page 1 of 2