5
Appendix
5.4 Status tables
Page 100
Docu-No.: 0590020601-EN Rev. 1.6.0
5.4.6
Actiflow drive hex status codes
Notes:
• Failure modes occur on bits 7 to 15, excluding 9
• These codes are displayed at the KCM interface
Bit
Function
Hex Code
0
1 = Activator Run. 0 = Stop.
0001
1
1 = safety switch closed. 0 = open.
0002
2
unused
0004
3
1 = Bit 1 Input activated (low level). 0 = not
activated, (high level).
0008
4
1 = Bit 2 Input activated (low level). 0 = not
activated, (high level).
0010
5
unused
0020
6
unused
0040
7
1 = Serial Master Time-out.
0080
8
unused
0100
9
1 = Relay 1 energized. 0 = off.
0200
10
1 = Displacement deviation
0400
11
1 = Current limit/short-circuit
0800
12
1 = Spring failure
1000
13
1 = General drive failure.
2000
14
unused
4000
15
1 = Sensor failure.
8000