Programming Reference
1
Product change menu 1.1
AUTO FF CALIB
This action permits easy feeder calibration. For this the program
parameter <CAL DC> and <CAL TIME> have to be entered. Material
is discharged for the value of <CAL TIME> and the starting feeding
factor is calculated.
Notes:
• Calibration can be canceled with
STOP
.
• Pressing
ENTER
instead of
RUN
as noted above will abort the
AUTOFFCALIB routine and return the user to the HOME menu.
• Performing an AUTOFFCALIB function on an already running
feeder will have no effect upon operation.
▲
This command will start the feeder. Make sure that nobody is
working on the machine.
For KSU-II/KCM select this parameter, press
ENTER
twice
and then press
RUN
For KSL press
MORE-F5
then press
then press
RUN
.
For KSC press
then
RUN
.
Attention:
Refilling and feeding errors during calibration reset the program pa-
rameter FF INIT to <0> and activate the <FEEDFACTOR ERR>
alarm.
CALIB REMAIN [s]
A count down timer for the auto calibrate cycle. It shows how many
seconds are left in the Calibration cycle.
INIT FF
Initial Feedfactor
Input of the starting feeding factor to determine the motor speed. The
Drive Command is calculated as follows:
DriveCommand(%) = 100 x (Setpoint/Initial Feedfactor)
The starting feed factor can also be calculated with the command
variable <AUTO FF CALIB>. Value of <0> will cause a Feedfactor
Alarm.
The feeder will not run with a Feedfactor of <0>.
Input range: 0 to 99999
Default: 100 kg/hr
Parameter