Docu-No.: 0590020601-EN Rev. 1.6.0
Page 93
Appendix 5
Programming the loader function 5.2
5.2
Programming the loader function
Use this procedure to program the KCM for the internal loader
function. This is not for the LSR/HCU loader function.
Note:
• The loader will only work if refill is enabled.
• Refill and loader can be interlocked with Run/Stop input of the
feeder controller. When programming <REFILL> to <If Running>,
the loader will only run if the feeder also runs.
• If a bit input is programmed to <Ldr Enable>, the loader will only
work if the corresponding bit input is activated.
• Section
discusses HCU programming parameters.
The Level Indicator must be placed so that it is covered when the
loader is full. The loader motor will stop and start based on this signal.
1. Connect the motor contactor to a relay output of the Drive Board
(e.g. REL 3).
2. Connect the Refill valve to a relay output of the Drive Board (e.g.
REL 2).
3. Connect the level indicator to a bit input of the Drive Board (e.g. IN
1).
4. In the I/O menu, program the following parameters:
– <MDU IN1> to <Loader Level>
– <MDU REL 3> to <Loader>
– <MDU REL 2> to <Refill>
5. In the security menu, change the security mode of the loader menu
to <RD/WR>. This will not be possible if a bit input is assigned to
DATA LOCK and the bit input is not activated. In this case, activate
the data lockout input or program the corresponding bit input in the
I/O menu to <None>.
6. In the Loader menu, program the <LOADER FUNCTION> to
<On>.
7. In the product change menu, program appropriate refill levels and
set <REFILL> to <Enable>.
The loader will start and the feeder will refill.
Fig. 5.9
KCM with Loader
motor
level indicator
refill signal
KCM
Содержание KSU-II/KCM
Страница 6: ...Page 6 Docu No 0590020601 EN Rev 1 6 0...