Maximum/Minimum On Time
Time interval corresponding to +/- 20% of the actual measured value for the
presence of ring tone.
Maximum/Minimum Off Time
Time interval corresponding to +/- 20% of the actual measured value for the
absence of ring tone.
Repetitions
Number of times that the unit verifies the tone it finds on calling the required
extension.
Busy Tone Parameters
The Busy Tone parameters correspond to the signal sent by the PBX to tell the
caller (in this case, the Vocal Server) that the extension to which the call was
transferred is busy.
Maximum/Minimum On Time
Time interval corresponding to +/- 20% of the actual measured value for the
presence of busy tone.
Maximum/Minimum Off Time
Time interval corresponding to +/- 20% of the actual measured value for the
absence of busy tone.
Repetitions
Number of times that the unit verifies the tone it finds on calling the required
extension.
Special Tone Parameters
The Special Tone parameters correspond to a signal which is different to the
two signals previously described for the PBX. In certain cases, the PBX may
send different tones for internal or external calls.
Maximum/Minimum On Time
Time interval corresponding to +/- 20% of the actual measured value for the
presence of tone.
Maximum/Minimum Off Time
Time interval corresponding to +/- 20% of the actual measured value for the
absence of tone.
Repetitions
Number of times that the unit verifies the tone it finds on calling the required
extension.