![Jusan Fonomail ProAttendant Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/jusan/fonomail-proattendant/fonomail-proattendant_installation-and-programming-manual_2034207043.webp)
AUTOMATIC ATTENDANT SETUP
43
6.4.2 Tones
•
Click “Tones” and the following screen appears. This screen allows for the
adjustment of the different tones’ detection parameters.
Common Parameters
Minimum Audio Level
This parameter is the tone/voice detection sensitivity level.
Minimum
Audio Level
Noise
Voice/Tone
Signal level
8
Silence Time
Minimum time during which the signal level on the line is lower than the
“Minimum Audio Level”, to determine if there is silence on the line.
Continuous Tone Duration
Minimum detection time of a line signal higher than the “Minimum Audio
Level”, to determine the presence of a continuous tone (dial tone).
Ring Tone Parameters
The Ring Tone parameters correspond to the signal sent by the PBX to tell the
caller (in this case, the Vocal Server) that the extension to which the call was
transferred is ringing.
Note:
It is only necessary to setup Ring Tone Parameters in the case that Supervised
or Consulted transfers have been previously selected.