High-burner
Low-burner
NATURAL GAS LL
Unscrew high-burner jet (fig. 20) and screw
No conversion
down the jet for gas LL acc. to chart I
LPG
Unscrew high-burner jet (fig. 20) and screw
Unscrew low-burner jet (fig. 22) and acc. to chart I
down the jet for LPG acc. to chart I.
screw down the setting jet for LPG until stop .
Open burners
Conversion from natural gas E to ...
CONVERSION TO OTHER TYPE OF GAS
Chart II
With conversion to a different type of gas fix a corresponding label!
Cooker setting
Burner spot
Auxiliary burner
Standard burner
Heavy-duty
Oven burner
burner
high
low
high
low
high
low
high
low
Natural gas "E"
Thermal load kW
1
0,33
2
0,45
3
0,65
3
0,85
20 mbar
H
5
= 37,78 MJ/m
3
Throughput of gas l/h
95
31
190
43
286
62
286
81
W
5
= 50,72 MJ/m
3
Marking of jets
70
E
96
E
119
E
116
E
Natural gas "LL"
Thermal load kW
1
0,33
2
0,45
3
0,65
3
0,85
20 mbar
H
5
= 32,49 MJ/m
3
Throughput of gas l/h
111
36
221
50
332
72
332
94
W
5
= 41,52 MJ/m
3
Marking of jets
74
E
106
E
133
E
128
E
LPG
Thermal load kW
1
0,33
2
0,45
3
0,65
3
0,85
50 mbar
H
5
= 125,81 MJ/m
3
Throughput of gas l/h
73
24
145
33
218
47
218
62
W
5
= 87,33 MJ/m
3
Marking of jets
43
23
60
28
75
35
76
40
THERMAL LOAD, THROUGHPUT OF GAS, MARKING OF JETS
The term „marking of jets“ is referring to the jet diameter in hundredth of mm. In case of jets marked with
„E“ the nominal values for thermal load and for throughput of gas are achieved by the setting of jets.
Chart I