49
GAS CONNECTION
On the back side (left and right) the cooker is provided
with two gas sockets R
1
/
2
“.
The gas connection must be accessible and provided
with a shutoff device.
Recommended is a safety gas socket. Same should be
located at the right or left, outside the radiation area. The
connection can be carried out rigid or by the use of a
DVGW-approved safety gas hose with socket acc. to
DIN 3383, page 1. In case the gas connection is not to
be carried out at the side prepared, but instead at the
other side, the closure will have to be loosened and
attached on the other side. Always insert a sealing
washer. Afterwards connect to the gas supply at the free
side.
When using the safety gas hose make sure that same is
not guided through hot zones, but freely installed.
After connection subject cooker and connection to a
sealing test.
PUTTING INTO OPERATION
Putting into operation to be carried out acc. to instructions
for use.
Ignite each open burner and check the burning stability
of high-burner and low-burner setting. (see par.: open
burner setting).
Heat up the oven burner for at least 10 minutes at
highest temperature setting. Then turn the oven control
knob to position 1. The burner must burn with a little, but
stable flame (see par.: oven burner setting).
After inspection: user to be instructed, function and
operation to be explained, instructions for use to be
handed over.
A Ramp end piece
B Round disk
C Ramp closure
GAS COOKER INSTALLATION
When installing the gas cooker a safety distance of 15
mm must be kept towards the adjacent furniture. If this
safety distance cannot be kept, a thermal insulation will
have to be located between the side panels and the
furniture.
Align the gas cooker horizontally. For that do horizontally
align the open burners by means of the set screws
mounted in the base and adapt the upper edge of
cooker to the adjacent furniture.
Fig. 17
FO 0063
Fig. 18
FO 0605
A
A
B
C