Changing the Management System IP Address
If you have installed the management system on a single server (in the standalone
configuration), and you move it later to a different server, then you need to reconfigure
the management IP address and port, enabling your managed devices to connect to it
at its new location.
To change the management system IP address:
1.
Update the Device Server IP on each managed device or set the secondary
management server IP to the new IP address.
2.
Log into the new NSM server as root.
3.
Navigate to
/usr/netscreen/DevSvr/var
.
4.
Open the Device Server configuration file (
devSvr.cfg
) in any text editor.
5.
Edit the values for the guiSvr.addr and guiSvr.port variables using the new IP address
and port number.
6.
Save the Device Server configuration file.
7.
Navigate to the utils directory. Run the .xdbUpdate utility to update the IP Address.
Run the following:
export LD_LIBRARY_PATH=/usr/netscreen/GuiSvr/utils/dbxml-2.2.13/lib
cd /usr/netscreen/GuiSvr/utils
./.xdbUpdate /usr/netscreen/GuiSvr/var/xdb server 0 0 /__/ip <IP Address>
./.xdbUpdate /usr/netscreen/GuiSvr/var/xdb server 0 1/__/ip <IP Address>
Note that the 0 represents the GUI Server ID and the 1 represents the Device Server.
You can view these IDs using the Server Manager in the NSM UI.
8.
Restart the GUI Server, and then restart the Device Server.
Changing the Device Server IP Address
If you have installed the management system on separate servers (in the distributed
configuration), and you later move the Device Server to a different server, you need to
reconfigure the management IP address and port enabling your managed devices to
connect to it at its new location. To do this, use the .xdbUpdate utility on the GUI Server.
To change the Device Server IP Address:
1.
Log into the server that is running the GUI Server as root. Navigate to the utils directory.
Run the .xdbUpdate utility to update the IP Address. Run the following:
export LD_LIBRARY_PATH=/usr/netscreen/GuiSvr/utils/dbxml-2.2.13/lib
cd /usr/netscreen/GuiSvr/utils
./.xdbUpdate /usr/netscreen/GuiSvr/var/xdb server 0 1/__/ip <IP Address>
Note that the 1 represents the Device Server. You can view this ID using the Server
Manager in the NSM UI.
2.
Restart the GUI Server.
Copyright © 2010, Juniper Networks, Inc.
174
Network and Security Manager Installation Guide
Содержание NETWORK AND SECURITY MANAGER 2010.4 - REV1
Страница 6: ...Copyright 2010 Juniper Networks Inc vi...
Страница 14: ...Copyright 2010 Juniper Networks Inc xiv Network and Security Manager Installation Guide...
Страница 22: ...Copyright 2010 Juniper Networks Inc xxii Network and Security Manager Installation Guide...
Страница 24: ...Copyright 2010 Juniper Networks Inc 2 Network and Security Manager Installation Guide...
Страница 42: ...Copyright 2010 Juniper Networks Inc 20 Network and Security Manager Installation Guide...
Страница 70: ...Copyright 2010 Juniper Networks Inc 48 Network and Security Manager Installation Guide...
Страница 92: ...Copyright 2010 Juniper Networks Inc 70 Network and Security Manager Installation Guide...
Страница 152: ...Copyright 2010 Juniper Networks Inc 130 Network and Security Manager Installation Guide...
Страница 214: ...Copyright 2010 Juniper Networks Inc 192 Network and Security Manager Installation Guide...
Страница 239: ...PART 3 Index Index on page 219 217 Copyright 2010 Juniper Networks Inc...
Страница 240: ...Copyright 2010 Juniper Networks Inc 218 Network and Security Manager Installation Guide...
Страница 244: ...Copyright 2010 Juniper Networks Inc 222 Network and Security Manager Installation Guide...