Table 20: EX Series Switch Environmental Tolerances
(Continued)
Switch or
device
Environment Tolerance
Altitude
Relative Humidity
Temperature
Seismic
EX3400
No performance
degradation up to
10,000 feet
(3048 meters)
Normal operation
ensured in the relative
humidity range 10%
through 85%
(noncondensing)
Normal operation ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX4200
No performance
degradation up to
10,000 feet
(3048 meters)
Normal operation
ensured in the relative
humidity range 10%
through 85%
(noncondensing)
Normal operation ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX4300
The maximum
thermal
output for
EX4300-48T
is 423 BTU/
hour and for
EX4300-48P
is 5844 BTU/
hour.
EX4300 switches
except the
EX4300-48MP
model— No
performance
degradation up to
10,000 feet
(3048 meters)
EX4300-48MP
model— No
performance
degradation up to
6,000 feet
(1829 meters)
EX4300 switches except
the EX4300-48MP
model— Normal
operation ensured in the
relative humidity range
10% through 85%
(noncondensing)
EX4300-48MP model—
Normal operation
ensured in the relative
humidity range 5%
through 90%
(noncondensing)
Normal operation ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX4500
No performance
degradation up to
10,000 feet
(3048 meters)
Normal operation
ensured in the relative
humidity range 10%
through 85%
(noncondensing)
Normal operation ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
40