2. Issue the command
show chassis temperature-thresholds
. This command displays the chassis
temperature threshold settings. Following is a sample output on an EX9208 switch. The output is
similar on other EX Series switches.
show chassis temperature-thresholds
(EX9208 Switch)
user@ host> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm Fire Shutdown
(degrees C) (degrees C) (degrees C) (degrees C)
Item Normal High Normal Bad fan Normal Bad fan Normal
Chassis default 48 54 65 55 80 65 100
Routing Engine 0 70 80 95 95 110 110 112
FPC 3 55 60 75 65 105 80 110
FPC 5 55 60 75 65 90 80 95
lists the output fields for the
show chassis temperature-thresholds
command. The
table lists output fields in the approximate order in which they appear.
Table 39:
show chassis temperature-thresholds
Output Fields
Field Name
Field Description
Item
Chassis component. You can configure the threshold information
for components such as the chassis, the Routing Engines, and FPC
for each slot in each FRU to display in the output. By default,
information is displayed only for the chassis and the Routing
Engines.
Fan speed
Temperature thresholds, in degrees Celsius, for the fans to operate
at normal and at high speed.
•
Normal—The temperature threshold at which the fans operate
at normal speed and when all the fans are present and
functioning normally.
•
High—The temperature threshold at which the fans operate at
high speed or when a fan has failed or is missing.
NOTE: An alarm is triggered when the temperature exceeds the
threshold settings for a yellow, amber, or red alarm.
153