Table 33: Parts Required for Connecting an EX Series Switch to Earth Ground
(Continued)
Switch
Earthing
Terminal
Location
Grounding
Cable
Requirements
Grounding Lug
Specifications
Screws and
Washers
Additional
Information
EX3200
and
EX3300
Rear panel of
the chassis
14 AWG
(2 mm²),
minimum 90° C
wire, or as
permitted by
the local code
Panduit
LCC10-14BWL or
equivalent—
not provided
•
Two
10-32 x .25 i
n. screws
with #10
split-lock
washer—
not provided
•
Two #10 flat
washers—
not provided
For EX3200
Switches, see
"Special Instructions
to Follow Before
Connecting Earth
Ground to an EX
Series Switch" on
page 89
.
EX3400
Rear panel of
the chassis
14-10 AWG
STR (2.5-6
mm²), minimum
90° C wire, or
as permitted by
the local code
Panduit
LCD10-10A-L or
equivalent—
not provided
•
Two
10-32 x .25 i
n. screws
with #10
split-lock
washer—
not provided
•
Two #10 flat
washers—
not provided
EX4200
Left side of
the chassis
14 AWG
(2 mm²),
minimum 90° C
wire, or as
permitted by
the local code
Panduit
LCC10-14BWL or
equivalent—
not provided
•
Two 10-32
x .25 in.
screws with
#10 split-
lock washer
—
not provided
•
Two #10 flat
washers—
not provided
See
Instructions to
Follow Before
Connecting Earth
Ground to an EX
Series Switch" on
page 89
.
85