Troubleshooting the Advanced Clocking Module
57
CHAPTER 9: Troubleshooting
Temperature
Instance : 0 Current Temperature(in Celcius) : 49
Instance : 1 Current Temperature(in Celcius) : 50
z
If the system LED on the front panel is lit red, use the
show chassis alarms
command to get
information about the source of an alarm condition and to get the status of the alarm.
cli@BX7000>
show chassis alarms
11 alarms are currently active
Alarm time Class Description
2000-01-01 00:01:55 UTC Other e1-0/0/0 : RED
2000-01-01 00:01:55 UTC Other e1-0/0/0 : Loss of Frame
2000-01-01 00:02:00 UTC Other e1-0/0/1 : RED
2000-01-01 00:02:00 UTC Other e1-0/0/1 : Loss of Frame
2000-01-01 00:01:55 UTC Other e1-0/0/0 : Alarm Indication
Signal
2000-01-01 00:02:00 UTC Other e1-0/0/1 : Loss of Signal
2000-01-01 00:01:48 UTC Other gige-1/0/1 : Link Down
Troubleshooting the Advanced Clocking Module
If the card is not inserted properly in the
Clock Card Expansion Bay
slot, the POST displays the error
message “card is not detected.”
To troubleshoot:
1.
Turn off the gateway.
2.
Remove the card from its slot and reinstall the card into the slot.
3.
After the gateway reinitializes, the card should be detected during POST.
4.
If the POST again displays the message “card is not detected,” the gateway has detected a
hardware failure.
5.
Contact the Juniper Networks Technical Assistance Center (JTAC) for instructions.
Содержание BX7000
Страница 10: ... x Copyright 2010 Juniper Networks Inc ...
Страница 12: ... xii Copyright 2010 Juniper Networks Inc ...
Страница 18: ...About This Guide xviii Requesting Support Copyright 2010 Juniper Networks Inc ...
Страница 20: ... 2 Copyright 2010 Juniper Networks Inc ...
Страница 36: ...CHAPTER 1 BX7000 Multi Access Gateway Overview 18 Advanced Clocking Module Copyright 2010 Juniper Networks Inc ...
Страница 60: ...CHAPTER 6 Grounding and Powering the Gateway 42 Powering Off the Gateway Copyright 2010 Juniper Networks Inc ...
Страница 64: ...CHAPTER 7 Accessing and Configuring the Gateway 46 Initial Setup Copyright 2010 Juniper Networks Inc ...
Страница 66: ... 48 Copyright 2010 Juniper Networks Inc ...
Страница 76: ...CHAPTER 9 Troubleshooting 58 Troubleshooting the Advanced Clocking Module Copyright 2010 Juniper Networks Inc ...
Страница 90: ... 72 Copyright 2010 Juniper Networks Inc ...
Страница 122: ... 104 Hardware Compliance Copyright 2010 Juniper Networks Inc ...
Страница 131: ...Copyright 2010 Juniper Networks Inc 113 Appendix E Declaration of Conformity ...
Страница 132: ... 114 Copyright 2010 Juniper Networks Inc ...
Страница 133: ...Copyright 2011 Juniper Networks Inc 115 PART 4 Index z Index on page 117 ...
Страница 134: ... 116 Copyright 2010 Juniper Networks Inc ...