03.13 EN
224
Fire extinguisher
Belt lock control
Heating
Clamping device
Air conditioning system
Agreed performance levels
W A B C
1
Check fire extinguisher is present, secure and Check test interval.
t
Chassis and Superstructure
W A B C
1
Test the belt lock control and check for damage.
t
Chassis and Superstructure
W A B C
1
Test the heating.
t
2
Replace heating breather.
t
3
Check hoses for leaks and damage and make sure they are secure.
t
Hydraulic operations
W A B C
1
Test the acknowledgement key.
t
2
Check axial play of the front and rear rollers and adjust if necessary.
t
3
Check attachment is properly secured to the truck and the
supporting elements.
t
4
Test attachment, check settings and check for damage.
t
5
Check sliding blocks are complete.
t
6
Check attachment bearing points, guides and stops for wear and
damage, grease and clean these components.
t
7
Check attachment lubrication; clean and lubricate if necessary.
t
8
Check hydraulic ports and tighten if necessary.
t
9
Check cylinder seals.
t
10 Check cylinder piston rods and bushings.
t
Chassis and Superstructure
W A B C
1
Test air conditioning system and its settings and check its
components for damage.
t
2
Note: The air conditioning system must only be serviced every two
years or 2000 service hours by specialist personnel.
3
Visually inspect the filter and replace if necessary.
t
4
Check temperature reading at the outlet of the ventilation nozzles
against manufacturer's ratings.
t
Содержание DFG 425s
Страница 1: ...DFG TFG 425s 435s G 10 07 Operating Instructions 51077936 51209061 01 09 03 13 ...
Страница 3: ......
Страница 5: ...03 13 EN 4 ...
Страница 15: ...03 13 EN 14 ...
Страница 24: ...23 03 13 EN ...
Страница 41: ...03 13 EN 40 ...
Страница 46: ...45 03 13 EN Fuelling is now complete ...
Страница 53: ...03 13 EN 52 ...
Страница 56: ...55 03 13 EN 2 Displays and Controls SOLO PILOT MULTI PILOT 7 78 78 81 81 80 80 75 75 77 76 74 79 79 ...
Страница 192: ...191 03 13 EN t Series equipment o Optional equipment ...