3.2
Liquid gas tank
Refillable liquid gas tanks contain a dispensing valve (71), a filling stop valve (69), a
relief valve (70) and a display (67).
Filling refillable liquid gas tanks (optional
equipment).
Requirements
– Note all guidelines and regulations
concerning the filling of LPG bottles on the
LPG pump.
Procedure
• Close the dispensing valve (71).
• Unscrew the cap (68) of the filling stop valve
(69).
• Screw the filling connection of the liquid gas
pump onto the filling stop valve (69).
Z
Fuelling automatically ends when the tank's
capacity has been reached.
• After fuelling, unscrew the filling connection and screw the cap (68) of the filling stop
valve (69) back on.
71
69 68
70
67