17
6 Technical data
6.5
Connecting cable
6.6
Environmental influences
6.7
Compliance with standards and directives
The standards applied to verify conformity with EU directives are listed in the EU type examination cer-
tificate and/or the EU declaration of conformity (if applicable).
Pressure:
According to Article 4 (1) of the Pressure Equipment Directive 2014/68/EU, the device may only be ap-
plied under the following conditions (depending on the maximum pressure and the DN of the piping used
for the medium):
Connection type
via two cable fittings M20 × 1.5
Cable data
Cable type
Shielded
Cross-section
0.5 to 1.5 mm
2
Cable diameter
When using one cable per cable fit-
ting
6 to 12 mm
When using two cables per cable
fitting
4 mm, with supplied multiway seal
Wire diameter
DN 15 to DN 400 (1/2 to 16″)
Fitting
Type 406090
Inlet and outlet sections
see "Inlet and outlet sections ", page 21
Operating temperature range
-10 to +60 °C (14 to 140 °F)
Storage temperature range
-20 to +60 °C (-4 to +140 °F)
Relative humidity
< 85 %, non-condensing
Height above sea level: max. 2000 m (6562 ft)
Protection type according to
EN 60529
IP65,
With connected device, screwed cable glands and screwed flap cover
EMC
EN 61000-6-3, EN 61000-6-2
Safety
EN 61010-1
Type of liquid (medium)
Requirements
Group 1 fluids, Article 4 (1) c.i.
Prohibited
Group 2 fluids, Article 4 (1) c.i.
≤ DN 32
Or > DN 32 and PN × DN ≤ 1000
Group 1 fluids,
Article 4 (1) c.ii.
≤ DN 25
Or PN × DN ≤ 2000
Group 2 fluids,
Article 4 (1) c.ii.
DN ≤ DN 200
Or ≤ PN 10
Or PN × DN ≤ 5000