24
WarNING :
• When using presser foot, throat plate and feed dog other than those delivered
as standard, needle may come in contact with throat plate and breaks, or feed
dog may come in contact with throat plate in case of some set values. Be sure
to perform the regulation of limitation values of
1
,
3
and
4
in accordance with
the gauge used. the regulation at the time of delivery is as follows :
Max. zigzag width : 8 mm
Max. feed amount : 5 mm
• When replacing the gauge, provide a clearance of 0.6 mm or more between
needle, and presser foot and throat plate, and between throat plate and feed dog.
(1) limitation of the max. zigzag width
• Max. zigzag width can be limited in accordance with the gauge.
• there are two kinds of limitations of max. zigzag width.
(1) Zigzag width symmetrical in the center
(2) specifying left/right positions
changeover of limiting procedure of max. zigzag width limitation value
(2) Specifying left/right positions
(1) Zigzag width symmetrical in the center
1) Press switch
1
.
2) Press switch
2
.
3) Figure on the left side
i s t h e z i g z a g w i d t h
symmetrical in the center
mode.
Every time switch
3
is
pressed, specifying left/
right positions and zigzag
width symmetrical in the
center can be changed
over alternately.
Max. zigzag width limitation value, reference of stitch base line, normal feed amount limitation
value and reverse feed amount limitation value are displayed when the power is turned ON.
1
: Max. zigzag width limitation value (Screen changes in case of specifying left/right positions.)
2
: Reference of stitch base line
3
: Max. reverse feed amount limitation value
4
: Max. normal feed amount limitation value
Display of max. zigzag width limitation value, reference of stitch base line, normal feed
amount limitation value and reverse feed amount limitation value can be performed
with ON/OFF.
6-2. Before setting the pattern
1
2
3
4
⇔
e
e
q
w
0.6
0.6
0.6