background image

FaxFinder

®

Fax Server

FF-240, FF-440, FF-840, FF240-IP Hardware and
Installation Guide

Содержание FaxFinder FF240

Страница 1: ...FaxFinder Fax Server FF 240 FF 440 FF 840 FF240 IP Hardware and Installation Guide ...

Страница 2: ... not designed manufactured or intended for use and should not be used or sold or re sold for use in connection with applications requiring fail safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death significant property damage or serious physical or environmental damage Examples of such use include life support machi...

Страница 3: ...inder FF240 IP Power Draw 10 FaxFinder x40 Power Draw 10 FF240 10 FF440 10 FF840 10 FaxFinder Expansion Modules Power Draw 10 FFEX8 11 FFEX16 11 Fax File Types 11 Requirements 11 Fax Routing Overview 12 Inbound Routing 12 Outbound Routing 13 Static or Dynamic Delivery 13 PBX Call Routing 13 Chapter 2 Hardware and Installation 15 Connectors and LEDs by Model 15 FaxFinder FF240 15 FaxFinder FF440 15...

Страница 4: ...Regulation Class A Devices 24 Fax Branding Statement 25 Canadian Limitations 25 Industry Canada Class A Notice 25 EMC Safety and R TTE Directive Compliance 25 Restriction of the Use of Hazardous Substances RoHS 26 REACH Statement 26 Registration of Substances 26 Substances of Very High Concern SVHC 26 Waste Electrical and Electronic Equipment Statement 27 WEEE Directive 27 Instructions for Disposa...

Страница 5: ...ncludes the following models FF240 IP FF240 2 modems FF440 4 modems FF840 8 modems Multi Tech provides the following manuals for use with FaxFinder Administrator Guide provides details on installing configuring and managing FaxFinder Specifications and Regulatory Information provides product specifications installation instructions and regulatory information User Guide provides details on sending ...

Страница 6: ...ger UL Listed or CSA Certified telecommunication Line cord Lithium Battery A lithium battery 3V coin cell CR1632 located within the product provides backup power for the timekeeping This battery has an estimated life expectancy of ten years When this battery starts to weaken the date and time may be incorrect Battery is not user replaceable If the battery fails the device must be sent back to Mult...

Страница 7: ...dditional power information see Power Draw Environment Operating Environment 22 to 185 F 30 to 60 C 1 Storage Environment 40 to 185 F 40 to 85 C Relative Humdity 20 to 90 noncondensing Fax Specifications Maximum T 38 Ports 8 Web Connections 50 File Upload Size2 48MB max for the Send Fax Web page 36MB max for T 37 Client software and API Certifications EMC Approvals FCC Part 15 Class A EN 55022 Cla...

Страница 8: ...r Draw for additional power information Environment Operating Environment 40 to 167 F 40 to 75 C 1 Storage Environment 40 to 185 F 40 to 85 C Relative Humdity 20 to 90 noncondensing Fax Specifications Fax Specs MT5634SMI modem Group 3 Fax T 30 and T 4 Modulations ITU V 34 ITU V 17 V 29 V 27 and V 21 Web Connections 50 File Upload Size2 48MB max for the Send Fax Web page 36MB max for T 37 Client so...

Страница 9: ...rs Connectors USB 2 0 High speed Mini B connector 8 or 16 RJ 11 line jacks Power Requirements Input Voltage 9 Volts Refer to FaxFinder Expansion Modules Power Draw for additional power information Environment Operating Environment 40 to 152 F 40 to 67 C Storage Environment 40 to 185 F 40 to 85 C Relative Humidity 20 to 90 noncondensing Certifications EMC Approvals FCC Part 15 Class A EN 55022 Clas...

Страница 10: ...ng or receiving faxes FaxFinder x40 Power Draw FaxFinder power draw at 12 volts FF240 Sleep Mode Typical1 Maximum2 Peak3 Current AMPS 0 665 0 711 0 837 0 959 FF440 Sleep Mode Typical1 Maximum2 Peak3 Current AMPS 0 801 0 890 0 930 1 07 FF840 Sleep Mode Typical1 Maximum2 Peak3 Current AMPS 0 965 1 100 1 210 1 38 Multi Tech Systems Inc recommends that the customer incorporate a 10 buffer into their p...

Страница 11: ...ile as TIF images Requirements The FaxFinder Fax Server is an IP enabled fax server that works with other devices and services on your communication network to send and receive faxes and to perform administrative functions FaxFinder requires The FaxFinder IP Fax Server works with other devices and services on your communication network to send and receive faxes and to perform administrative functi...

Страница 12: ...ent has a simple traditional switch or hub a managed V LAN switch that is IP address aware and will block traffic that is not from its configured subnet or a port on a network enabled device such as a PBX or router with controls that are similar to a managed switch FaxFinder s Ethernet interface is full duplex auto negotiating 10 100 1000 Mb and auto polarity sensing Auto polarity allows you to us...

Страница 13: ...essages to any user on your network Use this feature when your PBX can route multiple receiving numbers to a single station port A PBX may determine which number was dialed by the originator for example through an IP enabled PBX communicating directly with an IP based PSTN service or other IP enabled communication equipment PBX Call Routing 1 PBX sends a call to the FaxFinder by ringing the extens...

Страница 14: ...and Installation Guide If the PBX analog line cannot provide DID call routing incoming faxes will be routed solely on the delivery options associated with specific FaxFinder port line that the call was received on You can define multiple delivery options for each physical line port ...

Страница 15: ...are and Installation Guide 15 Chapter 2 Hardware and Installation Connectors and LEDs by Model FaxFinder FF240 FaxFinder FF240 Connectors FaxFinder FF240 LEDs FaxFinder FF440 FaxFinder 440 Connectors FaxFinder FF440 LEDs FaxFinder FF840 FaxFinder FF840 Connectors FaxFinder FF840 LEDs ...

Страница 16: ...der LAN 1 RJ 45 receptacle for network connection FaxFinder FF240 IP LEDs LED Descriptions Label Name Description Speed Speed When lit if the color is Green Ethernet rate is 1000 Mbps Yellow Ethernet rate is 100 Mbps Unlit Ethernet rate is 10 Mbps Link Act Link Activity Lit when a physical link has been established with the Ethernet network Blinks when there is activity HDD High Density Drive When...

Страница 17: ...1 8 or 1 16 PSTN POTS RJ 11 phone line ports The FaxFinder Expansion Module comes with either 8 ports or 16 ports Ports on the back line up with the modem LEDs on the front 9V Power receptacle for provided power cord USB Used to connect to FaxFinder LED Descriptions Label Name Description Power Power Solid constant green if module is on One set of the following for each modem port TD Transmit Data...

Страница 18: ...ectly on top of other equipment or place other equipment directly on top of the unit If installing the unit in a closed or multi unit enclosure ensure adequate airflow within the rack so that the maximum recommended ambient temperature 40 C is not exceeded Ensure that the unit is properly connected to earth ground by verifying that it is reliably grounded when mounted within a rack If a power stri...

Страница 19: ...ck mounting top view Dimensions with brackets attached for rack mounting front view Note Attaching the device to the rail of an EIA 19 inch rack enclosure may require two people 1 Position a mounting bracket on the right side as shown 2 Secure the bracket to right side using three provided screws as shown 3 Position a mounting bracket on the left side ...

Страница 20: ...ack enclosure per the rack manufacturer s mounting procedure Because equipment racks vary screws for rack rail mounting are not provided Follow the instructions of the rack manufacturer and use screws that fit Mounting FaxFinder on a Wall Use these steps to mount FaxFinder on a wall Dimensions with brackets attached for wall mounting top view Dimensions with brackets attached for wall mounting fro...

Страница 21: ...F 440 FF 840 FF240 IP Hardware and Installation Guide 21 2 Secure the bracket to the device using two provided screws 3 Position a mounting bracket on the left side using two mounting screw holes 4 Secure the bracket to the device using two provided screws ...

Страница 22: ...ess will cause data interference If your existing Ethernet network uses a 192 168 2 x subnet connect from the Administrative PC to the FaxFinder using an RJ 45 Ethernet cable and configure the FaxFinder s IP address to an IP address currently available on the Ethernet network Refer to Configuring FaxFinder s IP address and Network Settings When the FaxFinder s IP address has been configured you ca...

Страница 23: ...e telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 5 The telephone company may make changes in its facilities equipment operations or proce...

Страница 24: ...communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one ...

Страница 25: ...signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment Notice The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may...

Страница 26: ... Maximum Soldering temperature 260C in SMT reflow oven 1 Lead usage in some components is exempted by the following RoHS annex therefore higher lead concentration would be found in some modules 1000 PPM Resistors containing lead in a glass or ceramic matrix compound REACH Statement Registration of Substances After careful review of the legislation and specifically the definition of an article as d...

Страница 27: ...ments the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase The WEEE Directive covers all MultiTech products imported into the EU as of August 13 2005 EU based manufacturers distributors retailers and importers are obliged to finance the costs of recovery from municipal collection points reuse and recycling of specified percentages per the ...

Страница 28: ...mium CR6 Polybromi nated Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillators and Crystals X O O O O O Regulator O O O O O O Voltage Sensor O O O O O O Transformer O O O O O O Speaker O O O O O O Connectors O O ...

Страница 29: ...或有害物质 HS 的名称及含量水平方面的信息 有 有害 害 有 有毒 毒物 物质 质 元 元素 素 成 成分 分名 名称 称 铅 铅 PB 汞 汞 Hg 镉 镉 CD 六 六价 价铬 铬 CR6 多 多溴 溴联 联苯 苯 PBB 多 多溴 溴二 二苯 苯醚 醚 PBDE 印刷电路板 O O O O O O 电阻器 X O O O O O 电容器 X O O O O O 铁氧体磁环 O O O O O O 继电器 光学部件 O O O O O O ICs O O O O O O 二极管 晶体管 O O O O O O 振荡器和晶振 X O O O O O 调节器 O O O O O O 电压传感器 O O O O O O 变压器 O O O O O O 扬声器 O O O O O O 连接器 O O O O O O LEDs O O O O O O 螺丝 螺母以及其它五金件 X O O O ...

Страница 30: ...le cabling 22 connectors 17 LEDs 17 F fax regulations 25 routing overview 12 specifications 7 8 FCC Notice Class A 24 file types 11 upload size 7 8 H hazardous substances 26 I inbound fax overview 12 Industry Canada 25 Class A 25 input voltage 7 8 L LEDs expansion module 17 lithium battery 6 M mounting FaxFinder 18 O operating temperatures 7 8 outbound fax overview 12 P package contents 5 PBX call...

Страница 31: ...INDEX FaxFinder Fax Server FF 240 FF 440 FF 840 FF240 IP Hardware and Installation Guide 31 sécurité 7 T Telecom safety notice 6 temperature 7 8 TIF or TIFF 11 TXT 11 ...

Отзывы: