− 68 −
No.
Item
Setting range
/
Edit unit
Initial value
Changeover of compensation of flap concealed stitching position
using deflection detection
When the automatic deflection detection of left flap is not set, compensation of
flap concealed stitching is automatically performed using the second flap sensor.
*
When the automatic deflection detection is set, compensation of
flap concealed stitching is automatically performed regardless of
wth/wthout ths settng.
- - -
Used
Not used
Changeover of right/wrong side of material in the corner knife
setting screen
Material displayed in the corner knife setting screen is selected to right
sde dsplay or wrong sde dsplay.
- - -
Rght sde dsplay
Wrong sde dsplay
Stacker timer 5
Sets the waiting time of the stacker from the start of material grasping
operation to the release of the material
Ths settng s avalable when
"Grasping stacker (optional)" is used.
0.00 -
9.99/
0.01 sec
1.00 sec
Stacker timer 6
Sets the duration of operating the oscillating arm
Ths settng s avalable when
"Grasping stacker (optional)" is used.
0.00 -
9.99/
0.01 sec
1.50 sec
Number of stitches of grease-up
Number of stitches of sewing machine motion after replenishing
grease s ndcated.
*
When pressing CLEAR button, number of stitches is cleared to “0”.
Be sure to clear after replenishing grease.
- - -
- - -
Language selection
Language to be ndcated n the panel s selected.
- - -
No selecton
Japanese
Englsh
Chnese
(tradtonal)
Chnese
(simplified)
Spansh
Italian
French
German
Portuguese
Portuguese
Vetnamese
Korean
Indonesian
Russan
. . . Item that is not displayed due to other setting state.