– 159 –
1
CN1 : Power input
←
Power switch
CN3: Momentary interruption
detection signal
→
MAIN board
CN2 : Power output
→
MAIN board
Voltage changeover
Connected to 100V side
for 100V~120V or to
200V side for 200V~240V.
In the signal-phase mode, the
power supply is connected to
Pins 4-5. In the 3-phase mode,
the power supply is connected
to Pins 4-5-6.
7. Printed wiring board and dip switch
(1) Various printed wiring boards
1) FLT-T board
Single-phase 100V~120V
3-phase 200V~240V
Pulse generation is carried out for the
purposes of power supply rectification,
noise reduction, and the detection of a
momentary interruption
Содержание AMS-221EHL
Страница 185: ... 181 A JUKI Grease A B JUKI Grease B C Grease A A A A A A A B C C B B B B o MAIN SHAFT NEEDLE BAR COMPONENTS ...
Страница 190: ... 186 o X Y COMPONENTS 1 E C C C C C Grease E Three Bond 3060G Locktight 241 ...
Страница 191: ... 187 o X Y COMPONENTS 2 D D C C C D C C D C Grease D Grease D Locktight 241 ...
Страница 192: ... 188 C Grease D Grease D D C D C C D C D D C C D D D D D C D C o CLOTH FEED MECHANISM COMPONENTS D ...
Страница 231: ... 7 MAIN PANEL board circuit diagram 227 PANEL BOARD MAIN BOARD ...